Entry is a part of <b>Mechanomics</b> collection (10.6084/m9.figshare.c.5399826) that contains materials supporting findings presented in the following manuscript:<i>Urbanska, M., Ge, Y.</i> et al.,<br><b><i>De novo identification of universal cell mechanics gene signatures</i></b>BiorXiv: https://doi.org/10.1101/2021.04.26.441418<i>;</i><i> </i><i>first published:</i><i> </i>27th April 2021<i>, last updated:</i><i> </i>4th Nov 2024<br>eLife: https://doi.org/10.7554/eLife.87930<i>; first published:</i><i> </i>23rd March 2023<i>, last updated:</i><i> </i>27th Dec 2024<br>This dataset contains mechanical measurement of ECC4 and TGBC18TKB (TGBC) carcinoma cell lines conducted with with atomic force microscope (AFM).Measurements were performed using Nanowizard 4 (JPK Instruments, Germany).Tip-less cantilevers (PNP-TR-TL, nominal spring constant k = 0.08 N m<sup>−1</sup>, Nanoworld, Switzerland) decorated with a polystyrene bead of 5-µm diameter (PS-R-5.0, microParticles, Germany) each were used as the indenters.Following sub-folders are included under each sample:<br>• <b>Calibration </b>- contains data acquired during cantilever calibration<br>• <b>Ind </b>- indentation curves in .jpk-force format<br>• <b>Ind_processed-yyyy.mm.dd-hh.mm.ss</b> - results of processing of indentation curves with JPK data processing software (JPK DP, JPK Instruments)<br>• <b>Osc</b> - records of oscillatory measurements in .jpk-force format<br>• <b>Osc_processed-yyyy.mm.dd-hh.mm.ss</b> - results of processing of oscillatory measurements with JPK data processing software (JPK DP, JPK Instruments)<br>• <b>Pics</b> - bright-field images of cells acquired during the measurements, cantilever is located above the cell of interest
本条目属于<b>机械组学(Mechanomics)</b>数据集集合(DOI: 10.6084/m9.figshare.c.5399826),该集合包含支撑下述论文研究发现的相关材料:<i>Urbanska, M., Ge, Y.</i> 等人完成的<b><i>通用细胞力学基因特征的从头鉴定</i></b>。相关成果的预印本首次发布于BioRxiv:https://doi.org/10.1101/2021.04.26.441418,<i>首次发布时间:2021年4月27日,最后更新时间:2024年11月4日</i>;正式发表于eLife:https://doi.org/10.7554/eLife.87930,<i>首次发布时间:2023年3月23日,最后更新时间:2024年12月27日</i>。
本数据集包含采用原子力显微镜(atomic force microscope, AFM)对ECC4与TGBC18TKB(简称TGBC)癌细胞系开展的力学性能测试数据。测试使用德国JPK Instruments公司的Nanowizard 4型原子力显微镜完成。实验所用压头为经5μm直径聚苯乙烯微球(PS-R-5.0,德国microParticles公司)修饰的无针尖悬臂梁(PNP-TR-TL,标称弹簧常数k=0.08 N·m⁻¹,瑞士Nanoworld公司)。
每个样本下包含如下子文件夹:
• <b>Calibration</b>:包含悬臂梁校准过程中采集的原始数据
• <b>Ind</b>:格式为.jpk-force的压痕曲线数据
• <b>Ind_processed-yyyy.mm.dd-hh.mm.ss</b>:采用JPK数据处理软件(JPK DP, JPK Instruments)对压痕曲线进行处理后得到的分析结果
• <b>Osc</b>:格式为.jpk-force的振荡测量记录数据
• <b>Osc_processed-yyyy.mm.dd-hh.mm.ss</b>:采用JPK数据处理软件(JPK DP, JPK Instruments)对振荡测量数据进行处理后得到的分析结果
• <b>Pics</b>:测试过程中采集的细胞明场成像图,图中悬臂梁位于目标细胞上方
提供机构:
figshare