Experimental data for assessing sensitivity degradation in Force Sensing Resistors
收藏NIAID Data Ecosystem2026-03-10 收录
下载链接:
https://data.mendeley.com/datasets/tpjpcmnbxy
下载链接
链接失效反馈官方服务:
资源简介:
Data reports output voltages when testing FlexiForce sensors under cyclic loading conditions. This was done to assess sensitivity degradation using:
a) An inverting-amplifier circuit.
b) A voltage divider circuit.
The FlexiForce sensors were tested with circuits a) and b) at multiple sourcing voltages (1.25V; 2.5V; 5V; 7.5V). 16 Specimens of each sensor model were tested at the aforementioned conditions. Data in the files are organized as follows:
Column 1 through 3: Internal use, do not provide valuable information
Column 4: Nominal force applied to the sensors. It was used to close the force loops using load cell measurements in the test bench.
Column 5: Output voltage from Sensor 1
Column 6: Instantaneous force applied to the sensor at the moment of measuring.
本数据集记录了循环加载条件下FlexiForce传感器的测试输出电压数据,旨在通过两种电路配置评估其灵敏度衰减特性:
a) 反相放大电路;
b) 分压电路。
本次测试针对上述两种电路,在1.25V、2.5V、5V、7.5V多种供电电压下开展,每种传感器型号共制备16个试样,并均在上述条件下完成测试。
文件内的数据排布规则如下:
第1至3列:仅用于内部存档,无有效分析价值;
第4列:施加于传感器的额定作用力,该数据用于通过试验台内置测力传感器的读数实现力闭环控制;
第5列:传感器1的输出电压;
第6列:测量时刻施加于传感器的瞬时作用力。
创建时间:
2019-01-24