This database is composed of stator voltages and currents, field voltage and rotor position of a three-phase synchronous generator under resistive load. The data were acquired by means of two Tektronix MSO 2014B oscilloscopes with 4 channels each. Data were collected on 8 channels corresponding to phase voltages (Va,Vb,Vc), phase currents (Ia,Ib,Ic), field current of the generator (Ifd) and a pulse signal for angular position reference of the rotor (theta_m). For the simultaneous collection of the signals, a trip circuit was designed and implemented, the output of which was used as the triggering signal for the oscilloscopes. The synchronous generator was connected to a synchronous motor (Y-Y) and to a resistive circuit (18 units of 40W lamps) which served as loads. Voltage data were collected by means of a Keysight N2791 voltage probes; current data were collected using Tektronix A622 current tips. An PHCT203 optical key was used to collect rotor position pulse signal. The generator model is MOTROM M610-75-B-1K8-GS of 0.5 cv, 1800 rpm, 4 poles. The generator parameters obtained by means of physical bench tests were: Rs = 32.5 ohms (stator winding resistance) Rfd = 358.9 ohms (field winding resistance) Ld = 0.803H (direct axis stator inductance) Lq = 0.691H (quadrature axis stator inductance) Lls = 0.12H (stator winding leakage inductance) Lfd = 2.23H (field winding inductance) Vf = 64V (field voltage applied during the experiment, supplied by an regulated DC source) The database is composed by the following files of preprocessed data sampled at 10kHz in which the following variables are given, respectively, time, Va, Vb, Vc, Theta_r, Ia, Ib, Ic: 1) data0001.txt 2) data0002.txt 3) data0003.txt 4) data0001.csv 5) data0002.csv 6) data0003.csv Further, the database contains the following files of raw data: 1) T0001A.txt 2) T0001B.txt 3) T0002A.txt 4) T0002B.txt 5) T0003A.txt 6) T0003B.txt Each realization is contained in two files (suffixes A,B) and contain: Suffix A time CH1 (Va) CH1_peak (Va peak) CH2 (Vb) CH2_peak (Vb peak) CH3 (Vc) CH3_peak (Vc peak) CH4 (Theta_r) CH4_peak (Theta_r peak) Suffix B time CH1 (Ia) CH1_peak (Ia peak) CH2 (Ib) CH2_peak (Ib peak) CH3 (Ic) CH3_peak (Ic peak) CH4 (EMPTY) CH4_peak (EMPTY) When using the raw data, it is important to consider that the values were acquired in the following conditions: - Voltage probe scale: 100:1 - Current probe scale: 100mV/A - Oscilloscope probe scale: 10x - Oscilloscope configuration: check header of raw files. Contact information: jose.grzybowski@uffs.edu.br
本数据集涵盖电阻性负载工况下三相同步发电机的定子电压、定子电流、励磁电压及转子位置数据。
数据采集采用两台泰克(Tektronix)MSO 2014B型示波器,每台配备4个采样通道。本次采集共使用8个通道,分别对应三相相电压(Va、Vb、Vc)、三相相电流(Ia、Ib、Ic)、发电机励磁电流(Ifd)以及用于转子角位置参考的脉冲信号(theta_m)。
为实现多信号同步采集,研究人员设计并搭建了触发电路,其输出信号用作示波器的触发源。
该三相同步发电机连接至Y-Y接法的同步电动机,以及由18盏40W灯泡组成的电阻性负载。电压数据通过是德科技(Keysight)N2791型电压探头采集;电流数据采用泰克(Tektronix)A622型电流钳采集;转子位置脉冲信号则通过PHCT203型光电键采集。
本次实验所用发电机型号为MOTROM M610-75-B-1K8-GS,额定参数为0.5 cv、1800转/分钟、4极。通过台架物理测试得到的发电机参数如下:
定子绕组电阻$R_s=32.5Omega$,励磁绕组电阻$R_{fd}=358.9Omega$,直轴定子电感$L_d=0.803mathrm{H}$,交轴定子电感$L_q=0.691mathrm{H}$,定子绕组漏感$L_{ls}=0.12mathrm{H}$,励磁绕组电感$L_{fd}=2.23mathrm{H}$,实验中施加的励磁电压$V_f=64mathrm{V}$(由稳压直流电源提供)。
本数据集包含以下采样率为10kHz的预处理数据文件,各文件依次包含的变量为:时间、Va、Vb、Vc、Theta_r、Ia、Ib、Ic:
1) data0001.txt
2) data0002.txt
3) data0003.txt
4) data0001.csv
5) data0002.csv
6) data0003.csv
此外,数据集还包含以下原始数据文件:
1) T0001A.txt
2) T0001B.txt
3) T0002A.txt
4) T0002B.txt
5) T0003A.txt
6) T0003B.txt
每组实验数据均存储于两个文件(后缀分别为A、B)中,其中:
后缀为A的文件包含:时间、CH1(Va)、CH1峰值(Va峰值)、CH2(Vb)、CH2峰值(Vb峰值)、CH3(Vc)、CH3峰值(Vc峰值)、CH4(Theta_r)、CH4峰值(Theta_r峰值)
后缀为B的文件包含:时间、CH1(Ia)、CH1峰值(Ia峰值)、CH2(Ib)、CH2峰值(Ib峰值)、CH3(Ic)、CH3峰值(Ic峰值)、CH4(无数据)、CH4峰值(无数据)
使用原始数据时,需注意以下采集参数设置:
- 电压探头倍率:100:1
- 电流探头倍率:100mV/A
- 示波器探头倍率:10倍
- 示波器具体配置:请查阅原始数据文件的文件头