Aortic Thrombus after Coil Occlusion of a Type E Patent Ductus Arteriosus

收藏
PubMed Central2026-05-16 收录
下载链接:
https://pmc.ncbi.nlm.nih.gov/articles/PMC124762/
下载链接
链接失效反馈
官方服务:
资源简介:
A 5-year-old girl was referred to our institution for closure of a silent patent ductus arteriosus. Cardiac catheterization revealed a tiny-to-small patent ductus arteriosus of the elongated, conical type (Type E). Coil occlusion was performed with a Gianturco coil, 0.035-4 cm-3 mm. A follow-up echocardiogram showed a very small residual ductal shunt and a moderate-sized thrombus at the aortic end of the ductus arteriosus. The patient remained asymptomatic. (Tex Heart Inst J 2002;29:210–2)

一名5岁女童因无症状动脉导管未闭(silent patent ductus arteriosus)转诊至我院接受封堵治疗。心导管检查显示,患儿存在细长圆锥型(E型)微小至小型动脉导管未闭。术者采用规格为0.035-4 cm-3 mm的Gianturco弹簧圈(Gianturco coil)实施弹簧圈封堵术(coil occlusion)。随访超声心动图(echocardiogram)显示,患儿存在极少量残余导管分流,且动脉导管主动脉端可见中等大小血栓。患者始终无临床症状。(《德克萨斯心脏研究所杂志》(Tex Heart Inst J)2002;29:210–2)