five

Supercritical Carbon Dioxide Heat Transfer Data for 0.75 mm Square Microchannels with Horizontal, Single-Side Heated Boundary Condition at Reduced Pressure from 1.03 to 1.1

收藏
DataCite Commons2020-08-28 更新2024-07-27 收录
下载链接:
https://figshare.com/articles/Supercritical_Carbon_Dioxide_Heat_Transfer_Data_for_0_75_mm_Square_Microchannels_with_Horizontal_Single-Side_Heated_Boundary_Condition_at_Reduced_Pressure_from_1_03_to_1_1/7144247
下载链接
链接失效反馈
官方服务:
资源简介:
The attached heat transfer dataset was obtained at Oregon State University in the Thermal Energy Systems and Transport (TEST) Laboratory. Six different testing conditions were investigated with a total of 70 data points, varying the 1.) reduced pressure (P/P<sub>crit</sub> of 1.03 and 1.1), 2.) mass flux (500 and 1000 kg m<sup>-2</sup> s<sup>-1</sup>), 3.) inlet temperature (T<sub>in</sub> = 16 <sup>o</sup>C to 50 <sup>o</sup>C), and 4.) applied heat flux (q" = 20 and 40 W cm<sup>-2</sup>). The applied heat flux is on the bottom surface of a horizontal test section with a heated length of 20 mm, more dimension details can be found in the attached dataset and the reference.<br>This attached dataset contains both the measured experimental variables and calculated quantities. The wall temperatures, heat transfer coefficient, and corresponding uncertainty were evaluated using an integrated 2-D and 3-D modeling approach, described in the cited references. Some key details about the data are as follows:1. The values for each measured variable represent the average values of the raw data points (approx. 600) that were directly measured by various sensors.2. The attached file has 6 individual sheets which correspond to the 6 test cases considered in the current investigation.3. The attached file contains a detailed key which can be used to interpret the data set presented in each individual sheet. The sheets are named as, XX-YY-ZZ which represents the experimental conditions for the particular data set.• XX represents the reduced pressure• YY represents the mass flux in kg m<sup>-2</sup> s<sup>-1</sup>• ZZ represents the measured heat flux at the flux meter location in W cm<sup>-2</sup><br><br>

本附带的传热数据集采自俄勒冈州立大学热能系统与输运(TEST, Thermal Energy Systems and Transport)实验室。本次研究共设置6种不同测试工况,累计获取70组数据点,调控的实验变量包括:1)对比压力(reduced pressure,P/P_crit),取值为1.03与1.1;2)质量通量(mass flux),取值为500与1000 kg·m⁻²·s⁻¹;3)入口温度(T_in),范围为16℃至50℃;4)施加热流密度(applied heat flux,q"),取值为20与40 W·cm⁻²。施加的热流密度作用于水平测试段的底面,该测试段的加热段长度为20 mm,更多尺寸细节可参见附带数据集及所附参考文献。 本附带数据集同时包含实测实验变量与计算得到的物理量。研究采用集成二维与三维建模方法,对壁面温度、传热系数及对应不确定度进行了评估,相关建模方法详见所引用的参考文献。该数据集的关键细节如下: 1. 各实测变量的取值为各类传感器直接采集的原始数据(约600组)的平均值。 2. 附带文件包含6个独立工作表,分别对应本次研究中的6个测试工况。 3. 附带文件包含详细的数据说明表,可用于解读每个独立工作表中的数据集。各工作表采用XX-YY-ZZ的命名格式,代表对应数据集的实验工况: • XX代表对比压力 • YY代表质量通量,单位为kg·m⁻²·s⁻¹ • ZZ代表热流计测点处的实测热流密度,单位为W·cm⁻²
提供机构:
figshare
创建时间:
2018-09-27
二维码
社区交流群
二维码
科研交流群
商业服务