Color stability of a bulk-fill composite resin light-cured at different distances
收藏DataCite Commons2021-03-25 更新2024-07-28 收录
下载链接:
https://scielo.figshare.com/articles/dataset/Color_stability_of_a_bulk-fill_composite_resin_light-cured_at_different_distances/14287716/1
下载链接
链接失效反馈官方服务:
资源简介:
Abstract The aim of this in vitro study was to evaluate the color stability of a bulk-fill (Filtek One Bulk Fill, 3M ESPE) and a conventional (Filtek Z350 XT, 3M ESPE) composite resin light-cured at different distances, before and after being submitted to staining with a coffee solution. Sixty specimens of each composite resin were prepared and light-cured at distances of 0, 2 and 4 mm, using a LED light-curing unit (Valo, Ultradent). The specimens were separated (n = 10) for immersion in either distilled water or coffee solution (10 minutes a day for 8 days) to stimulate staining. Color evaluations were performed before and after immersion in the solutions, according to CIELab (△Eab), CIEDE2000 (△E00) and the Whiteness Index for Dentistry (△WID). Kruskal Wallis and Dunn tests, Mann-Whitney tests and Wilcoxon test were applied (α = 5 %). The a* value for conventional composite resin showed a significant increase after immersion in coffee and distilled water (p < 0.05). Both composite resins showed greater b* values when immersed in coffee than in distilled water, with no significant difference among the light-activation distances (p > 0.05). There was no significant difference for L* among the light-activation distances; both resins showed significant decrease in L* after immersion in coffee (p < 0.05). Color change (△Eab, △E00) and difference in whiteness (△WID) were higher for conventional resin when immersed in the coffee solution at all the light-activation distances. Conventional composite resin presented a higher staining value than bulk-fill composite resin, regardless of the light-activation distance.
摘要
本体外研究旨在评估分别以不同距离光固化的大块充填复合树脂(bulk-fill,Filtek One Bulk Fill,3M ESPE)与常规复合树脂(Filtek Z350 XT,3M ESPE)在经咖啡溶液染色前后的颜色稳定性。本研究共制备两种复合树脂试件各60个,采用LED光固化机(LED light-curing unit,Valo, Ultradent)分别以0、2、4 mm的距离进行光固化。将试件按每组10个分为亚组,分别浸泡于蒸馏水或咖啡溶液中(每日10分钟,持续8天)以模拟染色过程。分别在浸泡前后,依据CIELab色空间(△Eab)、CIEDE2000色差公式(CIEDE2000,△E00)及牙科用白度指数(Whiteness Index for Dentistry,△WID)开展颜色评价。统计学分析采用Kruskal-Wallis秩和检验、Dunn检验、Mann-Whitney U检验及Wilcoxon符号秩检验,检验水准α=0.05。常规复合树脂的a*值在经咖啡溶液及蒸馏水浸泡后均显著升高(p<0.05)。两种复合树脂经咖啡溶液浸泡后的b*值均高于蒸馏水浸泡组,且不同光固化距离间的b*值差异无统计学意义(p>0.05)。不同光固化距离间的L*值差异无统计学意义;两种复合树脂经咖啡溶液浸泡后L*值均显著降低(p<0.05)。在所有光固化距离下,常规复合树脂的色差(△Eab、△E00)及白度变化值(△WID)均高于大块充填复合树脂。无论光固化距离如何,常规复合树脂的染色程度均高于大块充填复合树脂。
提供机构:
SciELO journals
创建时间:
2021-03-25



