Repeatability and Reproducibility of Slit Lamp, Optical Coherence Tomography, and Scheimpflug Measurements of Corneal Scars

收藏
DataCite Commons2020-08-27 更新2024-07-27 收录
下载链接:
https://tandf.figshare.com/articles/Repeatability_and_Reproducibility_of_Slit_Lamp_Optical_Coherence_Tomography_and_Scheimpflug_Measurements_of_Corneal_Scars/8040140
下载链接
链接失效反馈
官方服务:
资源简介:
<b>Purpose</b>: To determine the repeatability and reproducibility of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug photography for several measurements of corneal scars, including scar size, scar depth, and corneal thickness. <b>Methods</b>: A series of patients treated for fungal keratitis at a tertiary eye care center in South India were recalled two years after successful treatment. Eyes with corneal scars had a slit lamp examination performed by two ophthalmologists masked to the other’s examination. For AS-OCT and Scheimpflug photography, each eye had two scans taken by one technician and a third scan taken by a separate technician. Scar measurements were subsequently assessed from AS-OCT images by three graders masked to each other’s results. Repeatability and reproducibility were assessed by calculating the intra-class correlation coefficient (ICC) from mixed effects linear regression models. <b>Results</b>: Fifty eyes had all measurements taken. The corneal scar size, measured as the geometric mean of the two longest perpendicular meridians, ranged from 0.8 to 5.4 (mean 2.8 mm, 95%CI 2.6 to 3.1). Scar size measurements taken by two separate individuals were most reproducible when the border of the scar was traced from the OCT (ICC 0.90, 95%CI 0.86 to 0.94), and least repeatable when assessed from slit lamp examination (ICC 0.80, 95%CI 0.70 to 0.90). <b>Conclusions</b>: AS-OCT and Scheimpflug imaging of corneal scars produced measurements with acceptable reproducibility that could be useful as cornea-specific outcomes for clinical trials.

研究目的:明确前节光学相干断层扫描(anterior segment optical coherence tomography,AS-OCT)与Scheimpflug摄影在角膜瘢痕多项测量指标(包括瘢痕尺寸、瘢痕深度及角膜厚度)中的重复性与复现性。 研究方法:召回印度南部某三级眼科中心内,于真菌性角膜炎治愈后两年的随访患者。对存在角膜瘢痕的患眼,由两名对彼此检查结果设盲的眼科医师完成裂隙灯检查。针对AS-OCT与Scheimpflug摄影,由一名技师为每只患眼完成两次扫描,另一名技师再完成第三次扫描。随后由三名对彼此评估结果设盲的评分者从AS-OCT图像中完成瘢痕尺寸测量。通过混合效应线性回归模型计算组内相关系数(intra-class correlation coefficient,ICC),以评估各项测量的重复性与复现性。 研究结果:共计50只患眼完成全部测量项目。以两条最长垂直径线的几何均值作为瘢痕尺寸的量化指标,其取值范围为0.8至5.4(平均值2.8mm,95%置信区间2.6至3.1)。当通过AS-OCT图像勾画瘢痕边界时,两名不同操作者的瘢痕尺寸测量结果复现性最优(ICC=0.90,95%置信区间0.86至0.94),而通过裂隙灯检查进行评估时,其复现性最差(ICC=0.80,95%置信区间0.70至0.90)。 研究结论:针对角膜瘢痕的AS-OCT与Scheimpflug成像测量结果具有可接受的复现性,可作为角膜特异性结局指标应用于临床试验。
提供机构:
Taylor & Francis
创建时间:
2019-04-25
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作