five

Evaluation of intake modifications at Bonneville Dam second powerhouse, 2001

收藏
NOAA Institutional Repository2025-12-23 更新2026-04-25 收录
下载链接:
https://repository.library.noaa.gov/view/noaa/50184
下载链接
链接失效反馈
官方服务:
资源简介:
In 1999, National Marine Fisheries Service studies of existing fish-guidance, biological, and hydraulic-model data concluded that flow conditions at Bonneville Dam Second Powerhouse were not conducive to high fish guidance efficiency (FGE) because ofinadequate flow entering the gatewell above the submersible traveling screen (STS). From these studies, the following three modifications were proposed to increase flow from the turbine intakes into the gatewell: 1) Remove a section of concrete beam to extend the vertical barrier screen (VBS); 2) Attach a turning vane to the STS; and 3) Install a gap closure device on the ceiling intake just downstream from the top edge ofthe STS. Contract no. W66QKZ80545753
提供机构:
NOAA
创建时间:
2025-12-23
二维码
社区交流群
二维码
科研交流群
商业服务