A modified SCBA facepiece for accurate metabolic data collection from firefighters

收藏
Taylor & Francis Group2016-01-19 更新2026-04-16 收录
下载链接:
https://tandf.figshare.com/articles/dataset/A_modified_SCBA_facepiece_for_accurate_metabolic_data_collection_from_firefighters/1289828/1
下载链接
链接失效反馈
官方服务:
资源简介:
To better assess the energy expenditure and exertion of firefighters during simulated firefighting activities, a commercial firefighter self-contained breathing apparatus (SCBA) facepiece was modified to interface with a portable metabolic monitoring device (Cosmed K4b<sup>2</sup>) while still functioning as a positive pressure SCBA air supply. To validate the device, standard National Fire Protection Association 1981 SCBA function tests were conducted and 14 subjects performed variable-workload assessments using all combinations of two test devices (Cosmed K4b<sup>2</sup> and metabolic cart) and two masks (modified SCBA facepiece and stock manufacturer-supplied breath collection). Metabolic data collected with the Cosmed K4b<sup>2</sup> via the modified facepiece were found to be accurate when compared to a ParvoMedics Truemax 2400 metabolic cart (average per cent difference: 4.6%). This modified facepiece design is suitable for use in metabolic studies requiring the utilisation of an SCBA system. Furthermore, the well-established overestimation of oxygen consumption from the Cosmed K4b<sup>2</sup> system was replicated.