five

Data for the validation studies presented in the paper "Motion Tracker: Camera-based Monitoring of Bodily Movements using Motion Silhouettes"

收藏
DataCite Commons2020-09-04 更新2024-07-27 收录
下载链接:
https://figshare.com/articles/dataset/Data_for_the_validation_studies_presented_in_the_paper_Motion_Tracker_Camera_based_Monitoring_of_Bodily_Movements_using_Motion_Silhouettes_/1425135/1
下载链接
链接失效反馈
官方服务:
资源简介:
We provide the raw data used in the validation study presented in our paper entitled "Motion Tracker: Camera-based Monitoring of Bodily Movements using Motion Silhouettes" for use by any interested parties. --------------------------------------------- Validation Study 1 Data --------------------------------------------- The data in this folder includes three sub-folders: 1) "back": time series at 4Hz recorded from the BPMS placed on the back of the chair<br>2) "seat": time series at 4Hz recorded from the BPMS placed on the seat of the chair<br>3) "motion": time series at 30fps recorded from the Motion Tracker run on recorded videos using the parameters specified in our paper Each sub-folder contains one text file per participant. Each text file is labeled with the participant number. Each participant has three associated text files, one in each sub-folder. This is the raw data; no pre-processing or outlier analysis has been performed. Please see the paper's "Validation Study 1" section for more information regarding the materials and recording procedure. --------------------------------------------- Validation Study 3 Data --------------------------------------------- The data in this folder includes: 1) "motion-kinect-5mindata.txt" - time series at 30Hz recorded from the Kinect. This is the raw data.<br>2) "kinect-outliers-removed.txt" - time series at 30Hz recorded from the Kinect, with outliers removed as described in the paper<br>3) "motion-outliers-removed.txt" - time series at 30fps recorded from the Motion Tracker run on the recorded video using the parameters specified in our paper, with outliers removed as described in the paper Please see the paper's "Validation Study 3" section for more information regarding the materials and recording procedure.

本团队向所有感兴趣的各方开放论文《运动追踪器(Motion Tracker):基于运动剪影的摄像头式身体运动监测》中验证研究所使用的原始数据。 --------------------------------------------- 验证研究1数据集 --------------------------------------------- 本文件夹内的数据包含三个子文件夹: 1) 「back」:放置于椅背上的BPMS采集的4Hz时间序列数据; 2) 「seat」:放置于椅座上的BPMS采集的4Hz时间序列数据; 3) 「motion」:基于本论文指定参数,通过对录制视频运行运动追踪器得到的30fps时间序列数据。 每个子文件夹中为每名参与者对应一个文本文件,文件名以参与者编号标注。每名参与者对应三个文本文件,分别存放在三个子文件夹中。本数据集为原始数据,未经过预处理或异常值分析。如需了解材料与录制流程的更多细节,请参阅论文中的「验证研究1」章节。 --------------------------------------------- 验证研究3数据集 --------------------------------------------- 本文件夹内的数据包含: 1) 「motion-kinect-5mindata.txt」——Kinect采集的30Hz时间序列原始数据; 2) 「kinect-outliers-removed.txt」——经论文所述方法移除异常值后的Kinect采集30Hz时间序列数据; 3) 「motion-outliers-removed.txt」——基于本论文指定参数,通过对录制视频运行运动追踪器得到的30fps时间序列数据,且已按论文所述方法移除异常值。 如需了解材料与录制流程的更多细节,请参阅论文中的「验证研究3」章节。
提供机构:
figshare
创建时间:
2016-01-19
二维码
社区交流群
二维码
科研交流群
商业服务