Supplementary Material for: Comparison of High-Flux, Super High-Flux, Medium Cut-Off Hemodialysis and Online Hemodiafiltration on the Removal of Uremic Toxins
收藏Figshare2022-10-10 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Supplementary_Material_for_Comparison_of_High-Flux_Super_High-Flux_Medium_Cut-Off_Hemodialysis_and_Online_Hemodiafiltration_on_the_Removal_of_Uremic_Toxins/21302889
下载链接
链接失效反馈官方服务:
资源简介:
Introduction: Online hemodiafiltration (OL-HDF) and hemodialysis (HD) using high-performance membranes such as adsorptive, medium cut-off (MCO), and super high-flux (SHF) dialyzers have been implemented to enhance the removal of middle molecules (MM). The aim of this study was to compare the efficacy of different dialysis strategies and dialyzers on small solutes and MM reduction ratio (RR) and mass removal. Methods: We performed a prospective study in 8 HD patients. Each patient underwent 9 dialysis sessions: seven sessions on HD using either Theranova 500™, Elisio 21H™, Renak PS-2.0W™, Filtryzer BK-2.1F™, Vie 21X™, TS-2.1UL™ or FDY 210-GW™ dialyzers and two sessions on OL-HDF using Elisio 21H™ or Renak PS-2.0W™ dialyzers. Results: Urea mass removal and RR were similar between all dialysis strategies. The lowest beta2-microglobulin RR was achieved with Filtryzer BK-2.1F™ HD (p p p p p p Conclusion: This study confirms that albumin loss and removal of MM are similar using conventional Elisio 21H™ OL-HDF, MCO-HD, and SHF type V dialyzers. Although Renak PS-2.0W™ OL-HDF provides high performance for MM depuration, this protein-permeable dialyzer should not be used in OL-HDF because of excessive albumin loss.
创建时间:
2022-10-10