five

TNCBF1-R-HSS: Taiwan Non-Seismic Concentrically Braced Frame (NCBF) with Repaired First Story and HSS Braces

收藏
DataCite Commons2020-08-19 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2012-1157.groups/Experiment-4
下载链接
链接失效反馈
官方服务:
资源简介:
The specimen designated TNCBF1-R-HSS consisted of a single-bay two-story concentrically braced frame with inverted V-bracing (chevron configuration) and a weak first story beam relative to the design post-buckled brace unbalanced load in the 2010 AISC Seismic Provisions. This frame was intended to be representative of a repaired non-seismic concentrically braced frame (NCBF) using in-plane buckling HSS braces. In-plane buckling braces could significantly reduce the gusset plate interface weld demands by eliminating out-of-plane gusset plate deformation. From the damaged TNCBF1-N-HSS speicmen, the first story braces and gusset plates were replaced with new HSS braces and connections compliant with SCBF design. Net section reinforcement plates were added to the second story corner brace connections but no other repair was made to the second story. Despite the in-plane buckling design, the first story braces buckled out-of-plane. The specimen was loaded quasistatically through the second story slab under a reversed cyclic increasing amplitude loading protocol. Traditional instrumentation and newer optical sensors were installed on the specimen. Portions of the specimen were whitewashed to detect yielding.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2015-01-20
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作