Column Splice Specimen 14C: PJP Flange Welds with Bolted Web
收藏DataCite Commons2020-07-28 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2012-1121.groups/Experiment-1
下载链接
链接失效反馈官方服务:
资源简介:
This specimen features PJP groove welds in the flanges and a bolted web splice. The test objectives are to determine whether PJP-welded column splices have sufficient toughness and strength to resist demand incumbent upon column splices in SMRF system in regions of high seismicity. The specimen was subjected to a cyclic loading protocol that was generated through assessment of splice demands determined from non-linear time history analyses of model building subjected to suites of ground motions. Each specimen was tested in three-point bending such that the splice location was subjected to the highest bending moments in the smaller column in addition to moderate-to-high shear forces. This splice specimen was able to successfully resist the entire loading protocol. The specimen failed when, at the splice location, the full bending strength of the smaller column was reached.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2013-08-30