five

Non-invasive estimation of absorbed ionizing radiation dose in mice using Near-Infrared Spectroscopy (NIRS) and aquaphotomics

收藏
DataONE2025-01-22 更新2025-04-26 收录
下载链接:
https://search.dataone.org/view/sha256:eee5ac06ce0879af63f37a254e39db3ac9f0a8e67bb86f0057a55a63279e0654
下载链接
链接失效反馈
官方服务:
资源简介:
Accurate measurement of ionizing radiation exposure, whether therapeutic or accidental, is of utmost importance in various scenarios. This paper presents a study that addresses this critical need by utilizing near-infrared (NIR) spectroscopy and aquaphotomics to estimate radiation dose exposure in mouse models subjected to X-ray irradiation. The analysis of NIR spectra acquired from the mouse abdomen enabled non-invasive estimation of radiation doses ranging from 0.5 to 6.5 Gy, immediately following the irradiation exposure. The findings were consistent with the impact of total body irradiation in mice, as evidenced by measures such as animal survival rate, alterations in body weight observed over a 30-day post-exposure period, and changes in hematocrit levels. The spectroscopic measurements were based on detecting changes in the molecular structure of body water after radiation exposure, utilizing the water spectral pattern as a multidimensional biomarker. While further validation in n..., Near infrared spectra acquisition was performed during a period of 30 days, at specific time points: prior to ionizing irradiation (after one week of acclimatization to laboratory conditions), immediately post-irradiation (0 h), and at 6, 12, 24, 48, and 72 hours, followed by subsequent measurements every 5 days until 30 days post-irradiation. At each measurement time, the spectra were collected from mouse abdomen using a portable, hand-held microNIR spectrometer (Viavi Solutions, Santa Rosa, CA, USA) in the spectral range 908 – 1670 nm, with approximately 7 nm resolution step. Five consecutive spectra were acquired for each mouse, at each time when the measurements were performed.  The spectral data were analyzed using multivariate analysis methods and preprocessed using extended multiplicative scatter correction. , , # Non-Invasive Estimation of Absorbed Ionizing Radiation Dose in Mice Using Near-Infrared Spectroscopy (NIRS) and Aquaphotomics [https://doi.org/10.5061/dryad.vq83bk41s](https://doi.org/10.5061/dryad.vq83bk41s) The dataset contains the near-infrared spectra of mouse abdomen acquired with the purpose of assessing and monitor the effects of exposure to ionizing irradiation. The experiments were conducted with female mice categorized into six groups, each exposed to specific levels of irradiation, ranging from 0 Gy (control) to 6.5 Gy (lethal dose). The study involved a testing window with longitudinal follow-ups over a one-month period, covering immediate post-exposure assessments (0h to 72h) and subsequent testing every 5 days until the one-month follow-up period concluded. After a week of acclimatization, 8-week-old mice were randomly divided into 6 groups with 8 mice per group (48 mice in total). Each mice group was then subjected to varying total body X-rays irradiation in doses of ...
创建时间:
2025-01-23
二维码
社区交流群
二维码
科研交流群
商业服务