This data provides nine detailed EnergyPlus files of an existing four-story apartment block located in Aarhus, Denmark. The third floor is modelled, which consist of five stairwells and ten apartments. The files can be used for building performance simulation and co-simulation with the building controls virtual test bed. The data contains IDF EnergyPlus files [3] of the third floor of an existing Danish four-story apartment block and eight retrofit scenarios. The block was built in 1978 and has only undergone minor refurbishments since then. The floor consists of five stairwells and ten apartments: one 1-room apartment (Apt. 9), four 3-room apartments (Apt. 1, 3, 5 and 7) and five 4-room apartments (Apt. 2, 4, 6, 8 and 10) with east-west oriented facades where the west oriented facades has unheated balconies. The stairwells and apartments were modelled as individual thermal zones with adiabatic horizontal surfaces (floor and roof). The stairwells are kept at a minimum temperature of 15°C. Further specification of geometry, materials and constructions can be found in the references [1] and [2]. The files can be used for building performance simulation and co-simulation with building controls virtual test bed [4, 5]. [1] T. H. Pedersen, R. E. Hedegaard, and S. Petersen, “Space heating demand response potential of retrofitted residential apartment blocks”, Energy and Buildings (2017). [2] R. E. Hedegaard, T. H. Pedersen, and S. Petersen, “Multi-market demand response using economic model predictive control of space heating in residential buildings”, Energy and Buildings (2017). [3] U.S. Department of Energy, “EnergyPlus 8.1.0,” [Online]. [4] Lawrence Berkeley National Laboratory, “Buildings Control Virtual Test Bed - BCVTB (1.4.0),” [Online]. [5] M. Wetter, “Co-simulation of building energy and control systems with the Building Controls Virtual Test Bed,” Journal of Building Performance Simulation (2010), vol. 3, no. 4, pp. 1-19, DOI: 10.1080/19401493.2010.518631.

本数据集包含9份详细的EnergyPlus(能源Plus)文件,对应丹麦奥胡斯市一栋既有四层公寓楼。研究针对该建筑的三层开展建模,该楼层包含5部楼梯间与10套公寓。 这些文件可用于建筑性能模拟,以及与建筑控制器虚拟测试台(Building Controls Virtual Test Bed,BCVTB)开展联合仿真。 本数据集包含该丹麦四层公寓楼三层的EnergyPlus IDF文件(输入数据文件)以及8种改造场景对应的文件。该公寓楼建于1978年,此后仅进行过少量翻新。 该三层包含5部楼梯间与10套公寓:1间单室公寓(公寓9)、4间三室公寓(公寓1、3、5和7),以及5间四室公寓(公寓2、4、6、8和10);其外立面呈东西向布置,西侧外立面带有未采暖阳台。 建模过程中,研究将楼梯间与公寓分别定义为独立热区,水平接触面(楼板与屋顶)采用绝热处理。楼梯间维持15℃的最低室温。 关于几何形状、材料与构造的更多细节可参见参考文献[1]与[2]。 上述文件可用于建筑性能模拟,以及与建筑控制器虚拟测试台开展联合仿真[4,5]。 [1] T. H. Pedersen、R. E. Hedegaard与S. Petersen,“改造型住宅公寓楼的空间采暖需求响应潜力”,《能源与建筑》(2017)。 [2] R. E. Hedegaard、T. H. Pedersen与S. Petersen,“基于住宅建筑空间采暖经济模型预测控制的多市场需求响应”,《能源与建筑》(2017)。 [3] 美国能源部,“EnergyPlus 8.1.0”,[在线]。 [4] 劳伦斯伯克利国家实验室,“建筑控制器虚拟测试台——BCVTB(1.4.0)”,[在线]。 [5] M. Wetter,“基于建筑控制器虚拟测试台的建筑能源与控制系统联合仿真”,《建筑性能模拟期刊》(2010),第3卷第4期,第1-19页,DOI:10.1080/19401493.2010.518631。
创建时间:
2024-01-23
搜集汇总
背景与挑战
背景概述
该数据集包含九个EnergyPlus模拟文件,基于丹麦一栋现有四层公寓楼的第三层建模,涵盖原始状态和八个改造场景,适用于建筑性能模拟和控制系统联合仿真。数据集详细描述了建筑结构,包括楼梯间和公寓的布局,并提供了几何与材料参考,主要用于能源效率研究和改造方案评估。
以上内容由遇见数据集搜集并总结生成
二维码
社区交流群
二维码
科研交流群
商业服务