five

Raw data from experiment on heat transfer, pressure drop and flow patterns of R1233zde(E) condensing inside horizontal 3 mm channel

收藏
DataCite Commons2026-04-30 更新2026-05-04 收录
下载链接:
https://mostwiedzy.pl/en/open-research-data/raw-data-from-experiment-on-heat-transfer-pressure-drop-and-flow-patterns-of-r1233zde-e-condensing-inside-horizontal-3-mm-channel,702062548748201-0
下载链接
链接失效反馈
官方服务:
资源简介:
Data contains raw measurements of heat transfer coefficient during condensation and raw phots of two phase flow done by high speed camera Photron UX100. Structure of xlm file: average values are at the top and raw measurements are below. Data is captured by National Instruments DAQ. Some values were typed manually, from apparatus which could not be connected to DAQ.  Average data form previous measurement is kept at the top of the file. Raw data is from the last collected average measurement. Name of phots contain reduced pressure, mass velocity and applied power – this way they should be connected with corresponding measurements. Number of photos added to dataset is limited to fit file size constrains.   U - Voltage at preheater I – Current at preheater, manual measurement Q - Electric power of preheater,  manual measurement t0 - temperature before preheater t1 - temperature after preheater, before condensation test section t2 -  temperature after condensation test section t8-t25 – temperature measurements at unused boiling test section p1 – pressure after test section p2 – pressure before test section pdiff – unused channel t5 - temperature ambient t6 - temperature of insulation t7- unused temperature measurement massflow – mass flow measurement at the main loop p_pre – pressure before preheater pl_I – pressure inside cooling loop I pl_II – pressure inside cooling loop II ML_1 – mass flow inside cooling loop I, manual measurement ML_2 - mass flow inside cooling loop II, manual measurement ai26 – unused channel tc3 – temperature before heat duty test section inside cooling loop II tc4 - temperature after heat duty test section inside cooling loop II tc20  - temperature after condensation test section inside cooling loop I tc21 - temperature before condensation test section inside cooling loop I tc22 – temperature after condensation test section inside main loop tc23 – temperature before condensation test section inside main loop ai11- unused channel This dataset was created as a result of the implementation of research project UMO-2021/41/N/ST8/04421 funded by the National Science Centre. Data was used in publication Głuch, S., & Mikielewicz, D. (2026). Experimental study of flow condensation of R1233ZD(e) at moderate and high saturation temperatures inside horizontal channel. Applied Thermal Engineering, 292(January). https://doi.org/10.1016/j.applthermaleng.2026.130157 Głuch, S. (2024). Flow condensation of new refrigeration fluids in minichannels at the parameters close to the thermodynamic critical point. Gdansk University of Technology.
提供机构:
Gdańsk University of Technology
创建时间:
2025-07-02
二维码
社区交流群
二维码
科研交流群
商业服务