Data contains raw measurements of heat transfer coefficient during condensation and raw phots of two phase flow done by high speed camera Photron UX100.
Structure of xlm file: average values are at the top and raw measurements are below. Data is captured by National Instruments DAQ. Some values were typed manually, from apparatus which could not be connected to DAQ. Average data form previous measurement is kept at the top of the file. Raw data is from the last collected average measurement. Name of phots contain reduced pressure, mass velocity and applied power – this way they should be connected with corresponding measurements. Number of photos added to dataset is limited to fit file size constrains.
U - Voltage at preheater
I – Current at preheater, manual measurement
Q - Electric power of preheater, manual measurement
t0 - temperature before preheater
t1 - temperature after preheater, before condensation test section
t2 - temperature after condensation test section
t8-t25 – temperature measurements at unused boiling test section
p1 – pressure after test section
p2 – pressure before test section
pdiff – unused channel
t5 - temperature ambient
t6 - temperature of insulation
t7- unused temperature measurement
massflow – mass flow measurement at the main loop
p_pre – pressure before preheater
pl_I – pressure inside cooling loop I
pl_II – pressure inside cooling loop II
ML_1 – mass flow inside cooling loop I, manual measurement
ML_2 - mass flow inside cooling loop II, manual measurement
ai26 – unused channel
tc3 – temperature before heat duty test section inside cooling loop II
tc4 - temperature after heat duty test section inside cooling loop II
tc20 - temperature after condensation test section inside cooling loop I
tc21 - temperature before condensation test section inside cooling loop I
tc22 – temperature after condensation test section inside main loop
tc23 – temperature before condensation test section inside main loop
ai11- unused channel
This dataset was created as a result of the implementation of research project UMO-2021/41/N/ST8/04421 funded by the National Science Centre.
Data was used in publication
Głuch, S., & Mikielewicz, D. (2026). Experimental study of flow condensation of R1233ZD(e) at moderate and high saturation temperatures inside horizontal channel. Applied Thermal Engineering, 292(January). https://doi.org/10.1016/j.applthermaleng.2026.130157
Głuch, S. (2024). Flow condensation of new refrigeration fluids in minichannels at the parameters close to the thermodynamic critical point. Gdansk University of Technology.