UT07, Steel Moment Resisting Frame with BFP Connections and Weak Panel Zone
收藏DataCite Commons2020-08-02 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2010-0985.groups/Experiment-7
下载链接
链接失效反馈官方服务:
资源简介:
Specimen UT07 was designed to model an interior joint of a steel moment resisting frame. The specimen consists of a single W14X398 A992 column with two W36X150 A992 beams attached to each flange. The subassemblage models a frame with approximately a 16 ft - 10 inches story height and a 29 ft - 8 inches beam span. The bolted flange plate (BFP) moment connection specimen was designed in accordance with Chapter 7 of the Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications (AISC 358-10), while it has weak panel zone strength to promote severe inelastic deformation of the panel zone. The specimen was subjected to cyclic loads at the top of the column by applying increasing levels of the story drift angle. The pre-determined loading sequence followed the AISC Seismic load protocol.
To simulate points of inflection under lateral load, the ends of the members were pin connected. The bottom of the column was connected to a high capacity clevis and the top of the column was rigidly attached to the loading crosshead, which can be controlled to simulate a pin. Each beam end was supported by two actuators that are intended to serve as a roller support. That is, the actuators were controlled to keep the beam ends at a constant elevation, and allow free horizontal translation and rotation of the beam ends. Lateral support frames were provided near the beam ends and the beam-to-column connection region.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2013-03-27