Paired t-test results of objective image quality.
收藏Figshare2023-06-15 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Paired_i_t_i_-test_results_of_objective_image_quality_/23526645
下载链接
链接失效反馈官方服务:
资源简介:
Increasing utilization of computed tomography (CT) has raised concerns regarding CT radiation dose and technology has been developed to achieve an appropriate balance between image quality, radiation dose, and the amount of contrast material. This study was planned to evaluate the image quality and radiation dose in pancreatic dynamic computed tomography (PDCT) with 90kVp tube voltage and reduction of the standard amount of contrast agent, compared with 100kVp PDCT of the research hospital’s convention. Total of 51 patients with both CT protocols were included. The average Hounsfield units (HU) values of the abdominal organs and image noise were measured for objective image quality analysis. Two radiologists evaluated five categories of image qualities such as subjective image noise, visibility of small structure, beam hardening or streak artifact, lesion conspicuity and overall diagnostic performance for subjective image quality analysis. The total amount of contrast agent, radiation dose, and image noise decreased in the low-kVp group, by 24.4%, 31.7%, and 20.6%, respectively (p k = 0.4−0.8). The contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and figure of merit of the almost organs except psoas muscle in the low-kVp group were significantly higher (p p