five

The response of the bicycle rider's body to vertical, fore-and-aft and lateral perturbations

收藏
NIAID Data Ecosystem2026-03-11 收录
下载链接:
https://zenodo.org/record/3246561
下载链接
链接失效反馈
官方服务:
资源简介:
In bicycles the rider’s mass is much larger than the vehicle’s mass. Hence, the rider influences the dynamic behaviour of the bicycle not only by means of voluntary control actions, but also by means of passive response of his/her body to bicycle oscillations. As a matter of fact, the rider’s body has inertial, stiffness and damping properties that are combined with the bicycle characteristics and affect the dynamic response of the whole system. More specific, the stabilization of dangerous oscillatory two-wheeler modes such as weave and wobble can be significantly influenced by the rider’s properties. For these reason, it is prerequisite to identify the passive response of the rider’s body to study the dynamic behaviour of the combined bicycle-rider system. To measure the rider response an instrumented bicycle mock up fitted with strain gauges at all interfaces has been developed. The frame was designed to recreate the geometry of a hybrid bicycle and has a reach to handlebars equal to 32 cm and a stack height to handlebars equal to 75cm. The bicycle mock-up was mounted on a top of a hexapod and was excited using  coloured noise perturbations in all 6 degrees of freedom (DoF). The force response of the rider body was measured at all bicycle interfaces. Two IMU's were also used to measure the transmissibility of the upper rider trunk. One IMU was placed on the base of the platform and one at the rider's sternum The repository contains the following folders and files: BSc thesis:  contains the report of bachelor student Toni Prats.pdf. CAD : contains the Solidworks drawings of the bicycle mock up. Data_analysis apparent mass (APMS) and seat-to-sternum transmissibility (STST) folders includes the mat.scripts to obtain the transfer functions (TRFs). Note: The data analysis method is described at passive rider identification.docx which is inside the Data_analysis apparent mass (APMS) folder. To plot the APMS transfer functions first run "interface_forces_24subs.m" (located in Force_Data folder) to obtain the required "force_signals_SI_t1_t2", afterwards copy paste the force_signals inside the analysis folder and run "TF_5_interfaces_24_subs.m" for the selected motion Ethnical: contains the ethics and technical device inspection approval which is prerequisite from TU Delft for human factor research. Force_data: contains the rider's force responses at all bicycle interfaces.  IMU_data and  IMU_data_Upper trunk includes the measured translational accelerations and angular velocities of the platform and rider's upper trunk. Labview: has the software used for data login the strain-gauge signals. Pictures: contains photos of the bicycle mock-up and subjects. PVA_signals: contains mat.script to generate the applied perturbation signals. Strain gauge calibration: includes the calibration and voltage sign and locations.xlsx which contain the voltage/force equations and force sign conventions for all bicycle interfaces respectively. Subjective data:  contains the NASA TLX data, mat.script. Supplementary paper material: Assymetric.xlsx contains the symmetric and  asymmetric elements of the dynamic force distribution. Coorelation.jpg shows the correlation between the performance and effort  scale of NASA "Raw-TLX". Schematic 1.jpg represents the trunk-pelvis system of the rider as a horizontal moving inverted pendulum, see discussion section of paper.
创建时间:
2020-02-05
二维码
社区交流群
二维码
科研交流群
商业服务