遇见数据集

Experimental sloshing pressure data from "Improving stability of moving particle semi-implicit method by source terms based on time-scale correction of particle-level impulses"

收藏
Zenodo2021-07-18 更新2026-04-07 收录
数据链接:
官方服务:

资源简介:

3D sloshing in a prismatic tank under translational coupled surge-sway (X and Y axis) motions. The main dimensions are height H<sub>T</sub> = 0.54m, width W<sub>T</sub> = 0.84m and length L<sub>T</sub> = 0.72m. The filling ratio of 50% (H<sub>F</sub> = 0.27m). The periods of surge and sway excitations are T<sub>s</sub> = 1.25s with amplitude motions of A<sub>x</sub> = 0.0144m (0.02 x length) and A<sub>y</sub> = 0.0168m (0.02 x width). Files: <strong>experimental_slosh_h50_20cycles_p1_dt0p000100.txt</strong>: Experimental pressure data at sensor P1 <strong>slosh_3d_exp_timer</strong>: Experimental movie <strong>sloshing_tank_dimensions.pdf</strong>: Tank main dimensions The experimental data was used in: Cheng, L.Y., Amaro Junior, R.A., Favero, E.H. (2021). Improving stability of moving particle semi-implicit method by source terms based on time-scale correction of particle-level impulses. Engineering Analysis with Boundary Elements, 131, 118-145. Available at. doi: https://doi.org/10.1016/j.enganabound.2021.06.018