Total Rotor Runout Dataset
收藏NIAID Data Ecosystem2026-03-13 收录
下载链接:
https://zenodo.org/record/5615523
下载链接
链接失效反馈官方服务:
资源简介:
Total Rotor Runout Dataset
Data of tactile multi-probe and eddy current displacement measurement of an electric motor rotor shaft surfaces.
Original measurement data related to publication:
T. Tiainen, R. Viitala, T.P. Holopainen, B. Hemming, Analysis of total rotor runout components with multi-probe roundness measurement method, Measurement, Volume 179, 2021, 109422, ISSN 0263-2241, https://doi.org/10.1016/j.measurement.2021.109422. (https://www.sciencedirect.com/science/article/pii/S0263224121004115)
All data is in raw format in CSV files. The measurements were triggered with a 1024-pulse rotary encoder and contain 5 rounds of data (5120 points).
The multi-probe roundness measurement algorithm implementations are available at: https://github.com/tuomastiainen/mpr-tools
Multi-probe roundness data, tactile measurement (Figures 6 and 9)
Raw data of four-point tactile roundness measurement.
Description
File name
z offset (mm)
Left polished surface four-point tactile measurement
roundness/left-polished.csv
477
Left journal bearing four-point tactile measurement
roundness/left-journal-bearing.csv
363
Left support bearing four-point tactile measurement
roundness/left-support-bearing.csv
0
Right support bearing four-point tactile measurement
roundness/right-support-bearing.csv
-1320
Right journal bearing four-point tactile measurement
roundness/right-journal-bearing.csv
-1575
Electrical runout data, simultaneous tactile and eddy current probe measurement (Figures 7 and 8)
Raw data of electrical roundness measurement, including one file with S1 and eddy data and another file with S1, S2, S3 and S4 tactile multi-probe roundness measurement data (simultaneous measurement, S1 data are equal in both files).
Description
File name
Left polished tactile and eddy current measurement
electrical-runout/left-polished.csv
Left polished four-point tactile measurement
electrical-runout/left-polished-roundness.csv
Scaling
All tactile probe readings (S1 to S4) will need to be multiplied by 1/409.6 to obtain the values of the probes in micrometers.
Eddy current probe data (analog voltage) was calibrated to the simultaneous eddy current probe measurement as described in the publication. The resulting calibration coefficient was 0.002130021300212892.
Names of variables
Variable
Description
n
Index number of measurement point (starting from rotary encoder reference pulse)
S1
Tactile displacement sensor 1
S2
Tactile displacement sensor 2
S3
Tactile displacement sensor 3
S4
Tactile displacement sensor 4
eddy
Eddy current sensor (voltage)
Acknowledgement
This dataset was obtained within the 19ENG07 Met4Wind project. This project has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme.
Project title: Metrology for enhanced reliability and efficiency of wind energy systems
Funder name: European Commission
Funder ID: 10.13039/100014132
Grant number: 19ENG07 Met4Wind
Link to project homepage: https://www.ptb.de/empir2020/met4wind/home/
Related objects: https://doi.org/10.1016/j.measurement.2021.109422
创建时间: