Dynamic System Identification on DBF - Rigid Links OFF - Ground Links ON - Loading Beams OFF
收藏Mendeley Data2024-01-31 更新2024-06-27 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2008-0648.groups/Experiment-10
下载链接
链接失效反馈官方服务:
资源简介:
System Identification Tests conducted in Lehigh University aim identifying DBF's dynamic characteristics, in terms of frequencies and mode shapes. The results will be used to model the frame for control purposes during RTHT. The tested structure has no loading beams and rigid links on brace points attached. Each in-plane and out-of-plane repetitions contain 10 to 20 hammer hits. In-plane tests took 400 seconds, out-of-plane and ambient vibration tests took 300 seconds. In this experiment ICP/PCB sensors are used. The structure is hit with an impact hammer to get the free vibration of the structure. The signal generated by hammer and sensors are collected by a top-of-edge DAQ system with a built-in ICP signal conditioner, VibPilot. Both sensors and DAQ system used for these experiments were non-NEES and are documented in the Documentation. The binary file of the collected data is converted with VibPilot software, SO Analyzer into MATLAB files.
创建时间:
2024-01-31