This study advanced the Next Generation (NG) CanCan protocols by implementing MHz compression for electric pulse packet delivery. Packets were delivered at 0.2 MHz, and the compression significantly reduced near-electrode cell ablation compared to delivery at 1 Hz, while preserving effects at the center. The experiments used a four-electrode array, with YoPro-1 to evaluate cell permeabilization and Propidium Iodide to assess cell death two hours post-delivery. This work was supported by NIH grant 1R21EY034258.