Marathon data.zip
收藏DataCite Commons2025-06-01 更新2024-08-18 收录
下载链接:
https://figshare.com/articles/dataset/Marathon_data_zip/22331686/1
下载链接
链接失效反馈官方服务:
资源简介:
Data accompanying manuscript Data of 7 runners during a Marathon is provided to accompany the manuscript “Quantifying and correcting for speed and stride frequency effects on running mechanics in fatiguing outdoor running”. For each runner the following files are provided: - Global Navigation Satellite System (GNSS) running speed - Inertial Measurement unit (IMU) running speed - Acceleration of foot sensor - Acceleration of lower leg/tibia sensor - Knee angles GNSS running speed GNSS running speed during the full marathon was based on different sports watches. Sampling frequencies between sports watches differed but was on average 0.7 (0.4) Hz. In line with the manuscript, missing latitude-longitude data was linearly interpolated before speed was computed as the distance between two latitude-longitude coordinates based on the Haversine formula. GNSS speeds above 20 km/h were deemed extremely unlikely and replaced with spline interpolation. GNSS speed was then resampled to 240 Hz to match the sampling frequency of the IMUs. Note that GNSS and IMU data are not yet time synchronized! - Filename: SubXX_gnss_speed.csv - Size of matrix: [1xN] IMU running speed IMU running speed was solely used for time synchronization of the GNSS running speed with IMU data. The scaled biomechanical model (as described in the manuscript) provided the velocity of the pelvis segment at 240 Hz. Pelvis IMU speed was then computed as the resultant pelvis IMU velocity. - Filename: SubXX_imu_speed.csv - Size of matrix: [Nx1] Acceleration of foot sensor Accelerations of the right foot were used for initial contact detection in the manuscript. 3D accelerations of a sensor on the right foot are provided in a sensor-fixed coordinate system. The sensor was placed on the midfoot within the shoes, the sensor was aligned with the long axis of the foot. The positive axis of the first dimension points towards the center of the ankle joint. The positive axis of the second dimension points to the right. The positive axis of the third dimensions is directed approximately upwards. - Filename: SubXX_rfoot_acc.csv - Size of matrix: [Nx3] Acceleration of lower leg/tibia sensor Accelerations of the lower leg were one of the quantities of interest in the manuscript. 1D acceleration of a sensor on the right lower leg at 240 Hz is provided in a sensor-fixed coordinate system. The sensor was aligned with the axial direction of the tibia. - Filename: SubXX_rtibia_acc.csv - Size of matrix: [Nx1] Knee angles Knee flexion/extension angles were one of the quantities of interest in the manuscript. Knee flexion/extension angles of the right lower leg at 240 Hz are provided. Knee flexion angles were defined 0° when the leg was fully extended during neutral standing. Flexion resulted in positive knee flexion angles. - Filename: SubXX_rknee_angle.csv - Size of matrix: [Nx1]
提供机构:
figshare
创建时间:
2023-03-24



