five

Percutaneous Image-Guided Biopsy for Non-Mass-Forming Isolated Splenomegaly and Suspected Malignant Lymphoma

收藏
NIAID Data Ecosystem2026-03-09 收录
下载链接:
https://figshare.com/articles/dataset/_Percutaneous_Image_Guided_Biopsy_for_Non_Mass_Forming_Isolated_Splenomegaly_and_Suspected_Malignant_Lymphoma_/1227751
下载链接
链接失效反馈
官方服务:
资源简介:
Background The aim of this study was to evaluate the accuracy, safety, and role of splenic biopsy in the management of patients with non-mass-forming isolated splenomegaly and suspected malignant lymphoma. Methods Between 2001 and 2013, 137 biopsies were performed under computed tomography (CT) fluoroscopic guidance in 39 patients. All patients had splenomegaly based on the CT findings and a suspected diagnosis of malignant lymphoma based on their clinical symptoms. The spleen was the only accessible site to perform a biopsy, and no mass lesions could be identified in the spleen. Results The overall sensitivity, specificity, and diagnostic accuracy of image-guided biopsy for malignant lymphoma were 88%, 100% and 92%, respectively. Major complications occurred in 3 patients. In 1 patient, transcatheter arterial embolization was performed due to hemorrhage, and two patients needed blood transfusion because of hematoma development, without the need for further treatment. Conclusions Image-guided splenic core-needle biopsy is a safe and accurate technique with a high diagnostic accuracy in most patients who with non-mass-forming isolated splenomegaly and suspected underlying malignant lymphoma.
创建时间:
2016-01-15
二维码
社区交流群
二维码
科研交流群
商业服务