遇见数据集

The RINEX Dataset to the IGS Receiver Antenna Ring Calibration Campaign 2022-2024 (IGS RingCalVal)

收藏
Zenodo2026-04-29 更新2026-05-26 收录
官方服务:

资源简介:

Dataset Information The Institut für Erdmessung at Leibniz University Hannover participated in the IGS ring receiver antenna calibration and validation campaign. During this campaign, raw data were collected on the laboratory roof of the institute. An external Rubidium clock, specifically a Stanford FS725 Benchmark known for its precision with an aging rate of 2×10^(−11), was used. The data also included information for a short baseline relative to the MSD8, using a similar type of receiver. For the antenna calibration, a JAVAD Delta TRE_S3S model was employed alongside a common clock ensemble to ensure accuracy. The offset from the mounting point to the antenna reference point (ARP) was carefully measured with a slide caliper and found to be precise as 0.2 mm. Additionally, reference coordinates for the setup were available to aid in the validation process. Table 1: Setup and instrumentation during data recording for IGS campaign validation Station RX IGS RX SNR Antenna Rx Antenna SN Calibration External Clock Mount System Comment [m] MSD5 JAVAD Delta TRE_S3S 04301 LEIAR25.R3 NONE 08360013 individual yes 0.08685 GREC installed 23.08.2022 MSD5 JAVAD Delta TRE_S3S 04301 TPSG5.A1 NONE 1327-10001 individual yes 0.08685 GREC installed 26.08.2022 MSD5 JAVAD Delta TRE_S3S 04301 TPSCR.G5C NONE 1367-10003 individual yes 0.08685 GREC installed 29.08.2022 MSD5 JAVAD Delta TRE_S3S 04301 HXCCGX601A NONE 30018172 individual yes 0.0698 GREC installed 22.12.2023 MSD5 JAVAD Delta TRE_S3S 04301 TRM57971.00 NONE 41112041 individual yes 0.0698 GREC installed 28.12.2023 MSD5 JAVAD Delta TRE_S3S 04301 JAVRINGANT_DM NONE 02099 individual yes 0.0698 GREC installed 04.01.2024 Content STATIC MEASUREMENTS (August 2022) 20220823 - LEIAR25.R3 NONE (08360013) - start measurements on MSD5 and MSD8 20220825 - firmware 4.2.01+b0-211117-066-92c3 seems to have problems in tracking Galileo E5A/E5B and AltBOC signals (no tracking) 20220826 - - end measurements on MSD5 and MSD8 (11:00 CEST) 20220826 - - changed firmware on 04301 from 4.2.01+b0-211117-066-92c3 to 4.2.01+b0-220213-066-92c3 (successful Galileo-tracking!) 20220826 - TPSG5.A1 NONE (1327-10001) - start measurements on MSD5 and MSD8 (start 11:55 CEST) 20220829 - - end measurements on MSD5 and MSD8 (14:00 CEST) 20220829 - TPSCR-G5C_NONE (1364-10003) - start measurements on MSD5 and MSD8 (start 14:52 CEST) STATIC MEASUREMENTS (December 2023) 20231222 - HXCCGX601A NONE (30018172) - start measurements on MSD5 and MSD8 (start: 16:45 CET) 20231228 - end (end: 13:35 CET) 20231228 - TRM57971.00 NONE (1112041) - start measurements on MSD5 and MSD8 (start 13:52 CEST) 20240104 - end (end: 09:57 CET) 20240102 - RINGANT_DM NONE (02099) - start measurements on MSD5 and MSD8 (start 10:24 CEST) 20240108 - - end (end: 08:28 CET) 2024-01-09 : TNC coax cable on the roof can cause problems, the TNC cable used for the connection between antenna and N-coax line could cause a problem (contraction due to extreme cold). Please check data, e.g. signal strength over days, by analysing data to ensure that there are no problems with the measurement data! Coordinates Table 2: Reference coordinates w.r.t. individual epochs for evaluation of PPP Station Frame Epoch X Y Z VX VY VZ [m] [m] [m] [m/a] [m/a] [m/a] MSD5 ITRF2014 2010.00 3845226.0692 658126.1967 5029187.4958 -0.0155 0.0164 0.0097 MSD5 ITRF2020 2023.98 3845225.8556 658126.4280 5029187.6303 -0.0155 0.0165 0.0095 MSD5 ITRF2020 2024.00 3845225.8553 658126.4283 5029187.6305 -0.0155 0.0165 0.0095 MSD5 ITRF2020 2024.01 3845225.8551 658126.4285 5029187.6306 -0.0155 0.0165 0.0095 MSD8 ITRF2014 2010.00 3845215.1461 658111.9014 5029197.6324 -0.0155 0.0164 0.0097 MSD8 ITRF2020 2023.98 3845214.9324 658112.1327 5029197.7669 -0.0155 0.0165 0.0095 MSD8 ITRF2020 2024.00 3845214.9321 658112.1331 5029197.7671 -0.0155 0.0165 0.0095 MSD8 ITRF2020 2024.01 3845214.9320 658112.1332 5029197.7672 -0.0155 0.0165 0.0095 Citation In case you like to cite this dataset, please use the following description. Kersten, T. (2025). The RINEX Dataset to the IGS Receiver Antenna Ring Calibration Campaign 2022-2024 (IGS RingCalVal). (1.0.0.) [Data set]. Leibniz University Hannover. https://doi.org/10.5281/zenodo.16878951

创建时间:
2025-08-14
二维码
社区交流群
二维码
科研交流群
商业服务