Cubic insulin data set collected from multiple lattices on i03 at Diamond Light Source
收藏资源简介:
Dataset collected as part of routine commissioning work, found to have more than one crystal present at the point where data were collected, allowing multiple lattices to be processed. While three lattices are present one is substantially weaker than the other two. Uploading to enable methods development and also to use for tutorials on how to use dials software. Processing data with the usual dials scripts (which will point to this deposition) result in statistics shown below. Tutorial to be uploaded to https://github.com/graeme-winter/dials_tutorials when available. -------------Summary of merging statistics-------------- Suggested Low High OverallHigh resolution limit 1.51 4.10 1.51 1.48Low resolution limit 54.89 54.93 1.54 54.89Completeness 98.9 100.0 83.7 95.3Multiplicity 54.7 78.1 4.6 53.5I/sigma 18.9 89.2 0.3 18.4Rmerge(I) 0.139 0.060 1.423 0.139Rmerge(I+/-) 0.138 0.060 1.316 0.138Rmeas(I) 0.140 0.061 1.590 0.140Rmeas(I+/-) 0.140 0.060 1.609 0.140Rpim(I) 0.016 0.007 0.683 0.016Rpim(I+/-) 0.023 0.009 0.894 0.023CC half 1.000 1.000 0.271 1.000Anomalous completeness 97.8 100.0 67.8 92.3Anomalous multiplicity 28.7 43.6 2.6 28.3Anomalous correlation 0.038 0.276 -0.050 0.049Anomalous slope 0.667 dF/F 0.060 dI/s(dI) 0.629 Total observations 669615 52255 2342 670277Total unique 12231 669 507 12529