遇见数据集

Formula prediction error PE (difference of the SEQ measured after cataract surgery minus the formula predicted SEQ) for the Hoffer Q (pACD), the Holladay 1 (SF), Haigis (a0/a1/a2), and Castrop formula (C / H / R).

收藏
NIAID Data Ecosystem2026-03-14 收录
官方服务:

资源简介:

SD refers to the standard deviation, 2.5% quantile and 97.5% quantile to the lower and upper boundary of the 95% confidence interval, and IQR to the interquartile range as the difference between the 75% and the 25% quantile. Formula constant optimisation was performed to minimise the sum of squared prediction errors PE. Situation A) refers to the ‘classical’ formulae with standard nK/nC values, with situation B) the formula constants and nK/nC in the main part of the formula were varied for optimisation, with situation C) the formula constants and nK/nC in the main part of the formula were varied to minimise for PE and the PE trend error over corneal radius, and with situation D) a standard optimisation was performed using the nK/nC value from situation B) derived from the other dataset in terms of a cross-validation.

创建时间:
2023-02-24
二维码
社区交流群
二维码
科研交流群