five

Samsung INR21700 30T 3Ah Li-ion Battery Data

收藏
Mendeley Data2024-03-27 更新2024-06-26 收录
下载链接:
https://data.mendeley.com/datasets/9xyvy2njj3
下载链接
链接失效反馈
官方服务:
资源简介:
The included tests were performed at McMaster University in Hamilton, Ontario, Canada by Dr. Phillip Kollmeyer (phillip.kollmeyer@gmail.com). If this data is utilized for any purpose, it should be appropriately referenced. See the Readme file for more details. A new 3Ah Samsung 3.0T cell was tested in an 8 cu.ft. thermal chamber with a 75amp, 5 volt Digatron Firing Circuits Universal Battery Tester channel with a voltage and current accuracy of 0.1% of full scale. /*************************************************/ A series of tests were performed at six different temperatures, and the battery was charged after each test at 1C rate to 4.2V, 10mA cut off charge current, at battery temperature of 25degC The tests were performed as follows: 1. Four pulse discharge HPPC test (1, 2, 6, and 12C discharge and 0.5, 1, 2, and 4C charge, with reduced values at lower temperatures) performed at 100, 95, 90, 80, 70..., 20, 15, 10, 5, 2.5 % SOC. ("..._HPPC.mat") 2. C/20 Discharge and Charge test. ("..._C20DisCh.mat") 3.0.5C ("..._Dis_0p5C.mat"), 2C ("..._Dis_2C.mat"), and two 1C ("..._Cap_1C.mat") discharge tests. The first 1C discharge test is performed before the UDDS cycle, and the second is performed before the Mix3 cycle. 4.Series of four drive cycles performed, in following order: UDDS(..._UDDS.mat), HWFET(..._HWFET.mat), LA92 (..._LA92.mat), US06 (..._US06.mat). 5. A series of eight drive cycles (mix 1-8) (..._Mixed#.mat) consist of random mix of UDDS, HWFET, LA92, US06. The drive cycle power profile is calculated for a single Turnigy cell in a compact electric vehicle. 6. The previous tests are repeated for ambient temperatures of 40degC, 25degC, 10degC, 0degC, -10degC, and -20degC, in that order. For tests with ambient temperature below 10degC, a reduced regen current limit is set to prevent premature aging of the cells. The drive cycle power profiles are repeated until 95% of the 1C discharge capacity at the respective temperature has been discharged from the cell 7. A series of 16 charges (charge 1-16) (..._Charge##.mat) store the cell charging before and after every drive cycle starting with an inital top up before doing the Cap_1C test /*************************************************/ Matlab (.mat) file naming convention: The file names begin with the date the test started, and are followed by the time the test started and a descriptive name, such as in the following example: "11-07-19_10.49 557_Cap_1C_40degC_IN21700_30T.mat? Date: "11-07-19" (November 7th, 2019) Time: "10.49" (10:49 am) Descriptor: "40degC_IN21700_30T" The naming convention allows for sorting by date and test time when all the files are placed in one folder. This may be useful when trying to determine which charge is associated with which drive cycle, for example, or when looking at aging.
创建时间:
2024-01-23
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作