aospsap3w1m.b1
收藏DataCite Commons2026-04-29 更新2025-04-09 收录
下载链接:
https://www.osti.gov/servlets/purl/1225037
下载链接
链接失效反馈官方服务:
资源简介:
The aospsap3w1m process reads in data from the aospsap3w.b1 datastream and applies a
dilution correction to the aerosol sample flow rate, and a filter loading correction to the
absorption coefficients. The filter loading is corrected by multiplying by the Weiss transfer
function f_w = 1/1.031 * 1/1.22 * (1/(1.0796 Tr + 0.71)) = 1 / (1.3579 Tr + 0.8931) where Tr is the
transmittance for a given wavelength. This form incorporates the initial PSAP transfer function
with modifications in Bond 1999 and subsequently in Ogren 2010. The one second (1s) data stream is
only created for BNL psap3w instruments where the 1 second samples are available. The one minute
(1m) data streams contain the averages of the one second data.
提供机构:
Atmospheric Radiation Measurement User Facility
创建时间:
2022-05-26