five

Maximum walking speed in multiple sclerosis assessed with visual perceptive computing

收藏
NIAID Data Ecosystem2026-03-10 收录
下载链接:
https://figshare.com/articles/dataset/Maximum_walking_speed_in_multiple_sclerosis_assessed_with_visual_perceptive_computing/5706556
下载链接
链接失效反馈
官方服务:
资源简介:
Background Gait is often impaired in people with multiple sclerosis (PwMS), but detailed assessment of gait impairment in research and care remains challenging. In a previous pilot study we reported the feasibility of visual perceptive computing (VPC) for gait assessment in PwMS using the Short Maximum Speed Walk (SMSW), which assesses gait on recording distances confined to less than 4 meters. Objective To investigate the equivalence of SMSW to rater-based timed 25ft. walk (T25FW) in a large cohort of PwMS, and to investigate the association of SMSW-derived gait parameters with clinical disability, as well as subjective and objective gait impairment, in order to validate the SMSW as a quick and objective measure of clinical relevance possibly superior to T25FW. Methods 95 PwMS and 60 healthy controls (HC) performed the SMSW using a VPC system with Microsoft Kinect. All participants received two immediate retests to establish test-retest-reliability. Both PwMS and HC performed the T25FW. PwMS were rated according to the Expanded Disability Status Scale (EDSS) and answered the 12-item Multiple Sclerosis Walking Scale (MSWS-12) as a measure of self-perceived walking impairment. Results PwMS showed reduced average speed (p<0.001) and higher mediolateral deviation (p = 0.002) during SMSW than HC. Average speed was the most reliable SMSW parameter in PwMS and HC (intra-class correlation coefficient (ICC) in PwMS = 0.985, and in HC = 0.977). Average speed declined with age in PwMS and HC (r in PwMS = -0.648, and in HC = -0.452, both p<0.001). Correlation of SMSW average speed and T25FW speed was high in both groups (r in PwMS = 0.783, and in HC = 0.747, both p<0.001) and mean difference (0.0013 m/s) between methods was below smallest detectable change. Average speed correlated well with both clinical disability based on EDSS (r = -0.586, p<0.001) and self-perceived walking impairment based on MSWS-12 (r = -0.546, p<0.001). Conclusion VPC-assessed walking parameters during SMSW can reliably detect gait disturbance in PwMS over very short distance. Specifically, maximum gait speed can be obtained with high accuracy in this simple test set-up. Cross-sectional associations with disability and self-perceived walking impairment support clinical relevance. Given its objectivity in a simple test set-up, SMSW is superior to T25FW.
创建时间:
2017-12-16
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作