five

Manuscript: Characterization testing of the Thales LPT9310-HP cryocooler

收藏
DataCite Commons2024-06-09 更新2025-04-16 收录
下载链接:
http://dataverse.jpl.nasa.gov/citation?persistentId=doi:10.48577/jpl.NF3TK7
下载链接
链接失效反馈
官方服务:
资源简介:
Two Thales LPT9310-HP commercial off-the-shelf (COTS) cryocoolers were parametrically performance tested for cold tip temperatures between 50 K and 250 K and heat rejection temperatures between 0°C and 40°C. Both coolers had identical transfer line configurations. The test results revealed small unit-to-unit thermodynamic performance variation. They are compared to test results of a COTS LPT9310 cooler with the same transfer line configuration. The effect of compressor temperature and pulse tube inclination angle are also discussed. In addition, the off-state heat leak as a function of inclination angle is presented. Finally, the feasibility of using a single LPT9310-HP COTS cooler in a two-stage configuration is discussed.