five

Research data supporting "Enhancing the Stability of Organolead Halide Perovskite Films Through Polymer Encapsulation"|钙钛矿材料数据集|材料稳定性数据集

收藏
Mendeley Data2023-02-23 更新2024-06-28 收录
钙钛矿材料
材料稳定性
下载链接:
https://www.repository.cam.ac.uk/1810/309586
下载链接
链接失效反馈
资源简介:
Data files here contain the XY data reported in graphs in the main manuscript and ESI. The file "Fig1B" contains the raw UV/Vis spectra for a CH3NH3PbI3-xClx film before (pristine) and after (degraded) thermal degradation, as well as PL data (emission) of pristine film. The first column contains the wavelength (X) data in nm. "Fig2" contains the raw PXRD data for CH3NH3PbI3-xClx films before thermal degradation (pristine) and after thermal degradation (uncoated and coated with the polymers PMMA, PC, EC, PMP). The first column contains the values of 2 θ (X) in degrees. “Fig3A" contains the raw UV/Vis spectra for a PMP-coated CH3NH3PbI3-xClx films degraded at 80°C for 0, 24, 48, 72, 96 and 144 hours. The first column contains the wavelength (X) data in nm. “Fig3B" provides the degradation time (X) in hours and difference in absorbance between 750 nm and 800 nm for CH3NH3PbI3-xClx films (uncoated and coated with the polymers PMMA, PC, EC, PMP) degraded at 60°C in air. “Fig3C" provides the degradation time (X) in hours and difference in absorbance between 750 nm and 800 nm for CH3NH3PbI3-xClx films (uncoated and coated with the polymers PMMA, PC, EC, PMP) degraded at 80°C in air. “Fig3D" provides the degradation time (X) in hours and difference in absorbance between 750 nm and 800 nm for CH3NH3PbI3-xClx films (uncoated and coated with the polymers PMMA, PC, EC, PMP) degraded at 100°C in air. “Fig8A" contains the raw data for the I-V curve of a CH3NH3PbI3-xClx film. Column 1 is voltage (V), column 2 is the current density (mA/cm2) for a pristine film and column 3 is for a thermally degraded film (heated at 100°C for 14 hours). “FigS2" contains the raw PXRD data for CH3NH3PbI3-xClx films (uncoated and coated with the polymers PMMA, PC, EC, PMP) before thermal degradation. The first column contains the values of 2 θ (X) in degrees. “FigS3A" contains the raw UV/Vis spectra for a CH3NH3PbI3-xClx film. Column 1 is wavelength (X) in nm, column 2 is the absorbance before PMMA coating and column 3 is the absorbance after PMMA coating. “FigS3B" contains the raw UV/Vis spectra for a CH3NH3PbI3-xClx film. Column 1 is wavelength (X) in nm, column 2 is the absorbance before PC coating and column 3 is the absorbance after PC coating. “FigS3C" contains the raw UV/Vis spectra for a CH3NH3PbI3-xClx film. Column 1 is wavelength (X) in nm, column 2 is the absorbance before EC coating and column 3 is the absorbance after EC coating. “FigS3D" contains the raw UV/Vis spectra for a CH3NH3PbI3-xClx film. Column 1 is wavelength (X) in nm, column 2 is the absorbance before PMP coating and column 3 is the absorbance after PMP coating. “FigS4" contains the raw UV/Vis spectra for polymer thin films, with wavelength (X) in nm and % transmittance for a substrate (blank), and PMMA, PC, EC,PMP thin films. “FigS5A" contains the raw UV/Vis spectra for uncoated CH3NH3PbI3-xClx films heated at 80°C for 0, 24, 48, 72, 96 and 144 hours. The first column contains the wavelength (X) data in nm. “FigS5B" contains the raw UV/Vis spectra for PMMA-coated CH3NH3PbI3-xClx films heated at 80°C for 0, 24, 48, 72, 96 and 144 hours. The first column contains the wavelength (X) data in nm. “FigS5C" contains the raw UV/Vis spectra for PC-coated CH3NH3PbI3-xClx films heated at 80°C for 0, 24, 48, 72, 96 and 144 hours. The first column contains the wavelength (X) data in nm. “FigS5D" contains the raw UV/Vis spectra for EC-coated CH3NH3PbI3-xClx films heated at 80°C for 0, 24, 48, 72, 96 and 144 hours. The first column contains the wavelength (X) data in nm.
创建时间:
2022-08-26
用户留言
有没有相关的论文或文献参考?
这个数据集是基于什么背景创建的?
数据集的作者是谁?
能帮我联系到这个数据集的作者吗?
这个数据集如何下载?
点击留言
数据主题
具身智能
数据集  4098个
机构  8个
大模型
数据集  439个
机构  10个
无人机
数据集  37个
机构  6个
指令微调
数据集  36个
机构  6个
蛋白质结构
数据集  50个
机构  8个
空间智能
数据集  21个
机构  5个
5,000+
优质数据集
54 个
任务类型
进入经典数据集
热门数据集

BC-MRI-SEG

BC-MRI-SEG是一个专注于乳腺癌MRI肿瘤分割的基准数据集,由中佛罗里达大学计算机视觉研究中心创建。该数据集整合了四个公开的MRI数据集,包括RIDER、ISPY1、BreastDM和DUKE,总计包含1320名患者的数据。这些数据集在MRI扫描仪的使用、配置及数据处理方法上各有不同,提供了多样化的数据来源。数据集的创建旨在解决医学影像领域中标记数据缺乏的问题,并推动开发适用于临床环境的稳健且适应性强的模型。BC-MRI-SEG的应用领域主要集中在乳腺癌的诊断和治疗评估,通过深度学习方法提高肿瘤分割的准确性和效率。

arXiv 收录

A00_13081a.jpg

Link to OCHRE database: http://pi.lib.uchicago.edu/1001/org/ochre/a8598ac4-9093-d548-30f3-84ce2ec953a7

DataONE 收录

Plant-Diseases

Dataset for Plant Diseases containg variours Plant Disease

kaggle 收录

TIMIT

TIMIT 阅读语音语料库的开发旨在为声学语音研究和自动语音识别系统的评估提供语音数据。 TIMIT 包含 630 个人/说话者的 8 种不同美式英语方言的高质量录音,每个人阅读多达 10 个语音丰富的句子。

OpenDataLab 收录

Materials Project 在线材料数据库

Materials Project 是一个由伯克利加州大学和劳伦斯伯克利国家实验室于 2011 年共同发起的大型开放式在线材料数据库。这个项目的目标是利用高通量第一性原理计算,为超过百万种无机材料提供全面的性能数据、结构信息和计算模拟结果,以此加速新材料的发现和创新过程。数据库中的数据不仅包括晶体结构和能量特性,还涵盖了电子结构和热力学性质等详尽信息,为研究人员提供了丰富的材料数据资源。相关论文成果为「Commentary: The Materials Project: A materials genome approach to accelerating materials innovation」。

超神经 收录