five

Shear Shock Waves Mediate Haptic Holography via Focused Ultrasound - Vibrometry Measurements with Elastomer Plate

收藏
NIAID Data Ecosystem2026-03-14 收录
下载链接:
https://zenodo.org/record/7686554
下载链接
链接失效反馈
官方服务:
资源简介:
Vibrometry Measurements with Elastomer Plate This dataset is part of a larger repository (DOI: 10.5281/zenodo.5248082) which houses links to the data used in the publication "Shear Shock Waves Mediate Haptic Holography via Focused Ultrasound" (Reardon et al., 2023). If you use these data please cite our publication (http://www.science.org/doi/10.1126/sciadv.adf2037). This dataset contains the response of a tissue phantom (Gelatin #2, Humimic) to focused ultrasound (UHEV1, Ultrahaptics). The data is provided as .mat files. The files are separated by scanning path (linear and zigzag trajectories) and scanning speed. Details about our experimental procedure can be found in our publication. IMPORTANT - The data provided is the unprocessed output from a laser doppler vibrometer (Ometron, model 8330). The data is NOT time-aligned and must be reconstructed using the reference signal and the map of the measurement locations.   Line Paths - Focused ultrasound scanned along a linear path on the surface of the tissue phantom at one of 5 speeds - 2 m/s, 4 m/s, 7 m/s, 11 m/s, and 15 m/s. The scanning speed is designated in the filename. Zigzag Paths - Focused ultrasound scanned along a zigzag path on the surface of the tissue phantom with longitudinal scanning speed vl = 3, 5 m/s. At both speeds, the ultrasound focus was modulated transverse to its primary motion direction at a speed, vmod, of +-2.5 m/s yielding a zigzag path (2 cm path width). The longitudinal scanning speed is designated in the filename.   Data Fields y (MxN) - 2D array containing the tissue phantom velocity normal to the laser doppler vibrometer (in mm/s) for N measurement locations. All repetitions are included as a single time-domain signal of M timepoints ref (MxN) - 2D array containing a reference voltage signal taken from the ultrasound phased array. Each of the N measured locations has a reference signal. The beginning of the reference signal identifies the start of a new repetition. nRepetitions - Number of stimulus repetitions (reps can be averaged to improve the measurement signal-to-noise ratio). fs - Laser doppler vibrometer sampling rate (in Hz) measurementLocations (Nx2) - 2D measurement locations on the gelatin surface (x,y; in m) for each of N measurement locations
创建时间:
2023-03-02
二维码
社区交流群
二维码
科研交流群
商业服务