five

Endoscopic real-synthetic over- and underexposed frames for image enhancement

收藏
Mendeley Data2026-04-18 收录
下载链接:
https://data.mendeley.com/datasets/3j3tmghw33
下载链接
链接失效反馈
官方服务:
资源简介:
------------------------------------------------------------------------------------------------------------------------------------------------------ For more information about this dataset please refer to our paper: https://arxiv.org/pdf/2207.02396.pdf ------------------------------------------------------------------------------------------------------------------------------------------------------ In endoscopy examinations, it is very common to come across with exposure errors due to light reflexions in the inner walls of the hollow organs. For instance, when the tip of the endoscope (which has a light) points to folds, these structures reflect the light, provoking overexposure, and whereas, an underexposed region at the other end of the frame can appear. This can be a big problem for physicians since they are fully responsible of detecting anomalies, blood, or even polyps, that could be translated in warning cases. Currently, methods for enhancing exposure errors need paired data, i.e., corrupted frames and their respective ground-truth (i.e., non-corrupted or clean image). For instance, for natural images the LOL or MIT-Adobe FiveK datasets, which contain common real life images have been proposed. These paired datasets allow researchers to both train and evaluate their models making use of standardized ground-truth images. To the best of our knowledge, in endoscopic domain, there are not publicly available in the literature. This is due to the difficulty of producing the same frame with and without exposures errors, naturally or with the help of a photo editing expert. Hence, our work aimed to create, through the use of GANs, a paired dataset of real images without any exposure error and the same image with an exposure error, that is a corrupted frame and its ground-truth. This dataset consists of three separate datasets containing i) normal endoscopic frames (without exposure errors), ii) synthetic overexposed frames, and iii) synthetic underexposed frames. Therefore, we have 1,231 real-overexposed pairs and 985 real-underexposed pairs; 2,216 paired frames in total, i.e., 4432 frames. Since our method for creating the synthetic data was stochastic, the distribution through the data varied in exposure intensity.
创建时间:
2022-09-15
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作