Discharge measurements collected downstream of Brandon Road Lock and Dam, Joliet, Illinois, USA in December 2014
收藏DataONE2017-09-30 更新2024-06-26 收录
下载链接:
https://search.dataone.org/view/098ef422-bdc5-49e5-827e-040bf475c144
下载链接
链接失效反馈官方服务:
资源简介:
Flow discharges were measured in the Des Plaines River immediately downstream of the Brandon Road Lock at river mile 286 on December 9, 2014 a using Teledyne RDI Rio Grande 1200 kHz acoustic Doppler current profiler (ADCP). The data were georeferenced with a differential GPS receiver with submeter accuracy. These flow discharge measurements were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS). ADCP data were collected and initially reviewed in the WinRiver II software. Final review of discharge measurements was completed using the QRev discharge computation and review software version 3.35 (Mueller, 2016). The output from QRev includes an XML document with the processed results, and is included here. A stylesheet (XLS) file is also included to enable easy viewing of the QRev processed results. Mueller, D.S., 2016, QRev—Software for computation and quality assurance of acoustic Doppler current profiler moving-boat streamflow measurements—User’s manual for version 2.8: U.S. Geological Survey Open-File Report 2016–1052, 50 p., http://dx.doi.org/10.3133/ofr20161052.
创建时间:
2017-10-05