five

Room temperature quantum emitters in aluminum nitride epilayers on silicon - data

收藏
Figshare2024-08-07 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Room_temperature_quantum_emitters_in_aluminum_nitride_epilayers_on_silicon_-_data/27277506
下载链接
链接失效反馈
官方服务:
资源简介:
Data supporting the publication "Room temperature quantum emitters in aluminum nitride epilayers on silicon" in APL. Photophysical data on 2 quantyum light sources grown via MOVPE and PVDNC is presented on samples grown on silicon. All data is saved in .csv files which can be opened in Excel. The first row/column is the x-axis variable and the second is the y-axis.The .csv files are named after the figures in which the data is presented.Figure 1MOVPE ----------------------------------------------------------------------------------------------------------------------------------Fig 1a.csv - 2D array of intensity values. X and Y axis are stored in the first row and column.Fig 1b.csv - 2D array of height values of the AFM map.Fig 1b Inset.csv - 2D array of height values of the inset AFM map.Fig 1c.csv - Intensity vs wavelength.PVDNC ----------------------------------------------------------------------------------------------------------------------------------Fig 1d.csv - 2D array of intensity values. X and Y axis are stored in the first row and column.Fig 1e.csv - 2D array of height values of the AFM map.Fig 1e Inset.csv - 2D array of height values of the inset AFM map.Fig 1f.csv - Intensity vs wavelength.Figure 2MOVPE ----------------------------------------------------------------------------------------------------------------------------------Fig 2a.csv - Delay time vs autocorrelation function.Fig 2b.csv - Intensity vs power. (Signal and background intensity in 2nd and 3rd columns).Fig 2c.csv - Intensity vs angle . (Signal and background angle and intensity in rows 1,2 and 3,4).PVDNC----------------------------------------------------------------------------------------------------------------------------------Fig 2d.csv - Delay time vs autocorrelation function.Fig 2e.csv - Intensity vs power. (Signal and background intensity in 2nd and 3rd columns).Fig 2f.csv - Intensity vs angle . (Signal and background angle and intensity in rows 1,2 and 3,4).Figure 3Fig 3a.csv - Delay time and autocorrelation function. Staggered powers from low to high.Fig 3b.csv - Timescales vs power.Fig 3c.csv - Autocorrelation coefficients vs power.Figure 4 Fig 4a.csv - Time vs normalised PL.Fig 4b.csv - Delay time vs pulsed autocorrelation. Research results based upon these data are published at https://doi.org/10.1063/5.0207744
创建时间:
2024-08-07
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作