TELE ECG Database: 250 telehealth ECG records (collected using dry metal electrodes) with annotated QRS and artifact masks, and MATLAB code for the UNSW artifact detection and UNSW QRS detection algorithms
收藏NIAID Data Ecosystem2026-03-09 收录
下载链接:
https://doi.org/10.7910/DVN/QTG0EP
下载链接
链接失效反馈官方服务:
资源简介:
------------------------------------------------------------------------------------------------------------- CITATION ------------------------------------------------------------------------------------------------------------- Please cite this data and code as: H. Khamis, R. Weiss, Y. Xie, C-W. Chang, N. H. Lovell, S. J. Redmond, "QRS detection algorithm for telehealth electrocardiogram recordings," IEEE Transaction in Biomedical Engineering, vol. 63(7), p. 1377-1388, 2016. ------------------------------------------------------------------------------------------------------------- DATABASE DESCRIPTION ------------------------------------------------------------------------------------------------------------- The following description of the TELE database is from Khamis et al (2016): "In Redmond et al (2012), 300 ECG single lead-I signals recorded in a telehealth environment are described. The data was recorded using the TeleMedCare Health Monitor (TeleMedCare Pty. Ltd. Sydney, Australia). This ECG is sampled at a rate of 500 Hz using dry metal Ag/AgCl plate electrodes which the patient holds with each hand; a reference electrode plate is also positioned under the pad of the right hand. Of the 300 recordings, 250 were selected randomly from 120 patients, and the remaining 50 were manually selected from 168 patients to obtain a larger representation of poor quality data. Three independent scorers annotated the data by identifying sections of artifact and QRS complexes. All scorers then annotated the signals as a group, to reconcile the individual annotations. Sections of the ECG signal which were less than 5 s in duration were considered to be part of the neighboring artifact sections and were subsequently masked. QRS annotations in the masked regions were discarded prior to the artifact mask and QRS locations being saved. Of the 300 telehealth ECG records in Redmond et al. (2012), 50 records (including 29 of the 250 randomly selected records and 21 of the 50 manually selected records) were discarded as all annotated RR intervals within these records overlap with the annotated artifact mask and therefore, no heart rate can be calculated, which is required for measuring algorithm performance. The remaining 250 records will be referred to as the TELE database." For all 250 recordings in the TELE database, the mains frequency was 50 Hz, the sampling frequency was 500 Hz and the top and bottom rail voltages were 5.556912223578890 and -5.554198887532222 mV respectively. ------------------------------------------------------------------------------------------------------------- DATA FILE DESCRIPTION ------------------------------------------------------------------------------------------------------------- Each record in the TELE database is stored as a X_Y.dat file where X indicates the index of the record in the TELE database (containing a total of 250 records) and Y indicates the index of the record in the original dataset containing 300 records (see Redmond et al. 2012). The .dat file is a comma separated values file. Each line contains: - the ECG sample value (mV) - a boolean indicating the locations of the annotated qrs complexes - a boolean indicating the visually determined mask - a boolean indicating the software determined mask (see Khamis et al. 2016) ------------------------------------------------------------------------------------------------------------- CONVERTING DATA TO MATLAB STRUCTURE ------------------------------------------------------------------------------------------------------------- A matlab function (readFromCSV_TELE.m) has been provided to read the .dat files into a matlab structure: %% % [DB,fm,fs,rail_mv] = readFromCSV_TELE(DATA_PATH) % % Extracts the data for each of the 250 telehealth ECG records of the TELE database [1] % and returns a structure containing all data, annotations and masks. % % IN: DATA_PATH - String. The path containing the .hdr and .dat files % % OUT: DB - 1xM Structure. Contains the extracted data from the M (250) data files. % The structure has fields: % * data_orig_ind - 1x1 double. The index of the data file in the original dataset of 300 records (see [1]) - for tracking purposes. % * ecg_mv - 1xN double. The ecg samples (mV). N is the number of samples for the data file. % * qrs_annotations - 1xN double. The qrs complexes - value of 1 where a qrs is located and 0 otherwise. % * visual_mask - 1xN double. The visually determined artifact mask - value of 1 where the data is masked and 0 otherwise. % * software_mask - 1xN double. The software artifact mask - value of 1 where the data is masked and 0 otherwise. % fm - 1x1 double. The mains frequency (Hz) % fs - 1x1 double. The sampling frequency (Hz) % rail_mv - 1x2 double. The bottom and top rail voltages (mV) % % If you use this code or data, please cite as follows: % % [1] H. Khamis, R. Weiss, Y. Xie, C-W. Chang, N. H. Lovell, S. J. Redmond, % "QRS detection algorithm...
创建时间:
2016-09-06