Optimized detection modality for radio-frequency sensing with a double resonance alignment magnetometer
收藏DataCite Commons2024-11-29 更新2025-04-17 收录
下载链接:
https://rdmc.nottingham.ac.uk/handle/internal/11588
下载链接
链接失效反馈官方服务:
资源简介:
In this work, we presented a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment magnetometer (DRAM). To verify theoretical predictions, experiments are carried out using a room-temperature paraffin-coated Caesium vapour cell and measuring either the polarization rotation or absorption of the transmitted laser light. A detailed experimental analysis of the resonance spectra is performed to validate the theoretical findings for various input parameters. The results signify the use of a single isotropic relaxation rate thus simplifying the data analysis for optimization of the DRAM. The sensitivity measurements are performed and reveal that the polarization rotation detection mode yields larger signals and better sensitivity than absorption measurement of light.
提供机构:
The University of Nottingham
创建时间:
2024-10-23