Supplementary Material for: Ventilated Infants Have Increased Dead Space and Lower Alveolar Tidal Volumes during the Early versus Recovery Phase of Respiratory Distress

收藏
DataCite Commons2020-08-26 更新2024-07-27 收录
下载链接:
https://karger.figshare.com/articles/Supplementary_Material_for_Ventilated_Infants_Have_Increased_Dead_Space_and_Lower_Alveolar_Tidal_Volumes_during_the_Early_versus_Recovery_Phase_of_Respiratory_Distress/11353772/1
下载链接
链接失效反馈
官方服务:
资源简介:
<b><i>Background:</i></b> Few studies have reported the measurement of anatomical dead space (V<sub>d,an</sub>) and alveolar tidal volume (V<sub>A</sub>) in ventilated neonates with respiratory distress. <b><i>Objective:</i></b> The aim of this study was to determine the differences in V<sub>d,an</sub> and V<sub>A</sub> in ventilated infants between the early and recovery phases of respiratory distress using volumetric ­capnography (V<sub>cap</sub>) based on ventilator graphics and capnograms. <b><i>Methods:</i></b> This study enrolled twenty-five ventilated infants (mean birth weight, 2,220 ± 635 g; mean gestational age, 34.7 ± 3.3 weeks). We adjusted respiratory settings to maintain appropriate oxygenation and tidal volume (V<sub>T</sub>), and performed V<sub>cap</sub> based on waveforms of ventilator graphics and capnograms. V<sub>d,an</sub> and V<sub>A</sub>were measured in infants with respiratory disorders, immediately after intubation (early phase) and subsequently when they were clinically stable (recovery phase). <b><i>Results:</i></b> The early phase, with lower dynamic lung compliance, required a higher level of ventilator support, not positive end-expiratory pressure, than the recovery phase. There were significant differences between the early and recovery phases for V<sub>d,an</sub> (mean difference in V<sub>d,an</sub>/kg = 0.57 mL/kg; 95% confidence interval [CI], 0.38–0.77; mean difference in V<sub>d,an</sub>/V<sub>T</sub> = 0.10; 95% CI, 0.07–0.14) and V<sub>A</sub> (mean difference in V<sub>A</sub>/kg = –0.60 mL/kg; 95% CI, –0.94 to –0.27; mean difference in V<sub>A</sub>/V<sub>T</sub> = –0.12; 95% CI, –0.15 to –0.09), despite no difference in V<sub>T</sub>. <b><i>Conclusions:</i></b> We evaluated changes in V<sub>d,an</sub> and V<sub>A</sub> during mechanical ventilation using V<sub>cap</sub> based on waveforms. The increase in V<sub>d,an</sub> and decrease in V<sub>A</sub> suggested dilation of the airways and collapse of the alveoli in ventilated infants with low lung compliance.
提供机构:
Karger Publishers
创建时间:
2019-12-11
二维码
社区交流群
二维码
科研交流群
商业服务