five

Data from: Managers' and physicians’ perception of palm vein technology adoption in the healthcare industry (Preprint) and Medical Identity Theft and Palm Vein Authentication: The Healthcare Manager's Perspective (Doctoral Dissertation)

收藏
DataONE2019-11-04 更新2024-06-08 收录
下载链接:
https://search.dataone.org/view/sha256:b0c80960b0999d61b33ba3032e4dbd2a60d6f33969060efdd2880f54026cf399
下载链接
链接失效反馈
官方服务:
资源简介:
Data from: Doctoral dissertation; Preprint article entitled: Managers' and physicians’ perception of palm vein technology adoption in the healthcare industry. Formats of the files associated with dataset: CSV; SAV. SPSS setup files can be used to generate native SPSS file formats such as SPSS system files and SPSS portable files. SPSS setup files generally include the following SPSS sections: DATA LIST: Assigns the name, type, decimal specification (if any), and specifies the beginning and ending column locations for each variable in the data file. Users must replace the \"physical-filename\" with host computer-specific input file specifications. For example, users on Windows platforms should replace \"physical-filename\" with \"C:\06512-0001-Data.txt\" for the data file named \"06512-0001-Data.txt\" located on the root directory \"C:\\". VARIABLE LABELS: Assigns descriptive labels to all variables. Variable labels and variable names may be identical for some variables. VALUE LABELS: Assigns descriptive labels to codes in the data file. Not all variables necessarily have assigned value labels. MISSING VALUES: Declares user-defined missing values. Not all variables in the data file necessarily have user-defined missing values. These values can be treated specially in data transformations, statistical calculations, and case selection. MISSING VALUE RECODE: Sets user-defined numeric missing values to missing as interpreted by the SPSS system. Only variables with user-defined missing values are included in the statements. ABSTRACT: The purpose of the article is to examine the factors that influence the adoption of palm vein technology by considering the healthcare managers’ and physicians’ perception, using the Unified Theory of Acceptance and Use of Technology theoretical foundation. A quantitative approach was used for this study through which an exploratory research design was utilized. A cross-sectional questionnaire was distributed to responders who were managers and physicians in the healthcare industry and who had previous experience with palm vein technology. The perceived factors tested for correlation with adoption were perceived usefulness, complexity, security, peer influence, and relative advantage. A Pearson product-moment correlation coefficient was used to test the correlation between the perceived factors and palm vein technology. The results showed that perceived usefulness, security, and peer influence are important factors for adoption. Study limitations included purposive sampling from a single industry (healthcare) and limited literature was available with regard to managers’ and physicians’ perception of palm vein technology adoption in the healthcare industry. Researchers could focus on an examination of the impact of mediating variables on palm vein technology adoption in future studies. The study offers managers insight into the important factors that need to be considered in adopting palm vein technology. With biometric technology becoming pervasive, the study seeks to provide managers with the insight in managing the adoption of palm vein technology. KEYWORDS: biometrics, human identification, image recognition, palm vein authentication, technology adoption, user acceptance, palm vein technology
创建时间:
2023-11-22
二维码
社区交流群
二维码
科研交流群
商业服务