资源简介:
This study deals with a frost-free household refrigerator-freezer, in which frosting can be retarded by dehumidifying the air before it enters the evaporator of the refrigerator-freezer via a desiccant-coated heat exchanger. Because the desiccant can be regenerated via the condensation heat of the refrigerant (which is exhausted into ambient air in conventional household refrigerator-freezers), the proposed system can achieve high energy efficiency. Calculations show that the coefficient of performance of this system (COP) is within the range 1.5 ~ 2.5 at an ambient temperature of 15 ~ 35 ºC. Moreover, calculation results show that the COP of the proposed frost-free system is increased by 6~17% compared to the conventional system.