five

Electromechanical impedance measurements using the Analog Devices AD5933

收藏
DataONE2015-05-21 更新2024-06-27 收录
下载链接:
https://search.dataone.org/view/sha256:a8e141491d0c826756a4edd8b9e8a5521d2e2cc662300d485585084b85867a2d
下载链接
链接失效反馈
官方服务:
资源简介:
Summary Raw and reorganised data of the electromechanical impedance of an Macro-Fiber Composite transducer bonded to a 6082 aluminium beam. The experiment was conducted over a range of damage levels (4) and temperatures (5, from 0°C to 40°C). A total of 320 measurements were carried out. Data was acquired using the Analog Devices AD5933 impedance analyser. Measurements were carried out in an environmental test chamber at the Surrey Space Centre, UK. Details This dataset contains raw output as well as aggregated data with the measurement software provided with the Analog Devices AD5933 evaluation board. All data in the dataset is 'tidy' (each variable forms a column, each observation forms a row). A total of 320 measurements are contained in this dataset - 4 damage levels and 5 temperature values, 16 iterations each. Multi-point calibration was performed with a 1% tolerance 470 Ohm resistor. A 1% tolerance 470 Ohm resistor was also placed in the Rfb location on the AD5933 evaluation board. The frequency sweep start frequency was 35 kHz, with delta frequency of 64 Hz and 512 increments. The internal oscillator of 16.776 MHz was used. The output excitation range was 1 V p-p. DDS settling time cycles was set to X2 (double). The experiment was conducted in an environmental test chamber, model WIR 12-30 produces by Design Environmental in 2002 for the Surrey Space Centre, UK. The chamber conforms to EN 50081-1 electromagnetic compatibility standards and has received periodic calibrations. Further information available upon inquiry (and in a forthcoming publication). Aggregated data The aggregated data contains the following variables: damdamage level - factor with 4 levels d0 ... d3 temptemperature in degrees Celsius iterinteration number freqfrequency magmagnitude of complex impedance argargument (phase) of complex impedance realreal part of complex impedance (resistance) imagimaginary part of complex impedance (reactance) Raw data Raw data in csv format contains the following variables: Frequency Impedancemagnitude of complex impedance Phaseargument of complex impedance, in degrees Realinternal real register value Imaginaryinternal imaginary register value Magnitudemagnitude of complex impedance before multiplying by the gain factor The filenames contain three metadata fields, separated with a dash: damage level (factor) temperature (degrees Celsius) iteration number Example: file d3-30-15.csv represents data acquired with damage level d3, at temperature of 30 degrees Celsius, iteration no. 15.
创建时间:
2023-11-21
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作