遇见数据集

Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays

收藏
NIST Chemistry WebBook2022-08-17 更新2026-03-14 收录
数据链接:
官方服务:

资源简介:

Dataset for multiple publishable figures in the paper entitled "Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays" submitted to Meas. Sci. and Tech. journal. Figure 3. (a) Pattern of pulses used to generate a dc voltage of 0.2 V, (b) difference from the nominal of the voltage measured using the K3458A versus dc bias current for different RF power biases. Figure 4. PD JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies. Figure 5. (a) Current-voltage characteristic of the CWD JJA and (b) the RF power-voltage characteristic of the PD JJA. The error bars show the Type-A uncertainty (k=1) of the measurement of five measurements. Figure 6. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement. Figure 7. Allan deviation for 0 V. See text for details. Figure 8. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement. Figure 9. Allan deviation at 1 V.

二维码
社区交流群
二维码
科研交流群
商业服务