Exergetic analysis of reverse brayton cryocooler for different cooling loads at 65 K for HTS cables.
收藏DataCite Commons2020-09-19 更新2025-04-16 收录
下载链接:
http://iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0021703&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈官方服务:
资源简介:
Cryocoolers with cooling capacity of 1-5 kW at 65 K are required to operate the high-temperature superconductors (HTS) power cables. In this paper, an RBC for cooling of HTS cables is analysed and optimized using Aspen HYSYS V8.6®. Exergy approach has been adopted to analyse the RBC. The optimization problem developed based on exergy efficiency maximization. Three load conditions of 1, 3 and 5 kW at 65 K with neon and helium as working fluids have been considered. Additionally, the effects of variation of operating parameters on the performance of the systems were identified, and the effects of turbine and compressor efficiencies and heat exchanger effectiveness have been studied. As a result, the cycle configurations with optimum process parameters have been identified and presented in this work. The conclusions of this article will be helpful in deciding modification in basic different cooling loads.
提供机构:
International Institute of Refrigeration (IIR)
创建时间:
2017-10-18