five

Quality assessment of the included studies.

收藏
NIAID Data Ecosystem2026-05-01 收录
下载链接:
https://figshare.com/articles/dataset/Quality_assessment_of_the_included_studies_/22711692
下载链接
链接失效反馈
官方服务:
资源简介:
Background Surface Electromyography (sEMG) has been used to monitor respiratory muscle function and contractility in several clinical situations, however there is the lack of standardization for the analysis and processing of the signals. Objective To summarize the respiratory muscles most assessed by sEMG in the critical care setting and the assessment procedure details employed on those muscles regarding electrode placement, signal acquisition, and data analysis. Methods A systematic review of observational studies was registered on PROSPERO (number CRD42022354469). The databases included PubMed; SCOPUS; CINAHL, Web of Science and ScienceDirect. Two independent reviewers ran the quality assessment of the studies using the Newcastle-Ottawa Scale and Downs & Black checklists. Results A total of 311 participants were involved across the 16 studies, from which 62.5% (10) assessed the diaphragm muscle and 50% (8) assessed the parasternal muscle with similar electrode placement in both of them. We did not identify common patterns for the location of the electrodes in the sternocleidomastoid and anterior scalene muscles. 12/16 reported sample rate, 10/16 reported band-pass and 9/16 reported one method of cardiac-interference filtering technique. 15/16 reported Root Mean Square (RMS) or derivatives as sEMG-obtained variables. The main applicabilities were the description of muscle activation in different settings (6/16), testing of reliability and correlation to other respiratory muscles assessment techniques (7/16), and assessment of therapy response (3/16). They found sEMG feasible and useful for prognosis purposes (2/16), treatment guidance (6/16), reliable monitoring under stable conditions (3/16), and as a surrogate measure (5/16) in mechanically ventilated patients in elective or emergency invasive procedures (5/16) or in acute health conditions (11/16). Conclusions The diaphragm and parasternal muscles were the main muscles studied in the critical care setting, and with similar electrodes placement. However, several different methods were observed for other muscles electrodes placement, sEMG signals acquisition and data analysis.
创建时间:
2023-04-27
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作