This study aimed to evaluate the performance of the second set of flat-sheet UF membranes (UC4) using a custom-built filtration setup as described in GCP cards in Task 2.4. The tests were conducted in LENN lab in May and June 2025. The objective was to observe membrane behavior, specifically mechanical stability, permeability and contaminant rejection, under controlled laboratory conditions. Flat sheet characterization was performed on membranes made with TIPS and NIPS method and samples with and without lipophobic surface treatment with Nafion.