five

Digital image correlation experiments involving in-plane loading of a composite laminate

收藏
NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://zenodo.org/record/13880114
下载链接
链接失效反馈
官方服务:
资源简介:
---------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------------------------------  SUMMARY  --------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------------------------------------------------------------------------   Stereo-DIC 5 MPx system was used to perform experiments on a composite laminate. Thickness = 2.48 mm Layup is [0, 45 -45 90]2s leading to quasi-isotropic behaviour   ---------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------------------------------  FOLDERS  --------------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------------------------------------------------------------------------   Image sets:   Sample 1: monotonically loaded up to 7.2 kN. Sample 2: monotonically loaded up to 10 kN.Sample 3: loaded cyclically with increasing peak load to study the presence of permanent strains.   Each folder contains the following subfolders: stationary: stationary images for DIC noise evaluation calib: calibration target images for stereo-DIC calibration using MatchID software test: images of the test sample being loaded, with force.csv including load reading from the uniaxial test bench synced with the images.      ---------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------  SUPPORTING NINFORMATION -------------------------------------------------------------------- ----------------------------------------------------------------------------------------------------------------------------------------------------------------------    Each calibration image folder contains a *.caldat file with intrinsic and extrinsic stereo camera parameters identified by MatchID 2024.2 DIC package.
创建时间:
2024-10-06
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作