Ice temperature time-series from sensors installed in boreholes drilled into Khumbu Glacier, Nepal, in 2017 and 2018 as part of EverDrill research project - VERSION 2.0
收藏Mendeley Data2024-06-25 更新2024-06-27 收录
下载链接:
https://data.bas.ac.uk/full-record.php?id=GB/NERC/BAS/PDC/01523
下载链接
链接失效反馈官方服务:
资源简介:
Temperatures were acquired by using Honeywell UNI-curve 192-502-LET-AOI negative temperature coefficient thermistors, controlled by Campbell Scientific CR1000 data loggers from the glacier surface. Details are provided in Miles et al. (2018). Resolution: The thermistors have an interchangeability of 0.4 degrees Celsius. After an ice bath calibration, previous studies have suggested that an accuracy of +/- 0.05 degrees can be achieved around 0 degrees. This is therefore the expected accuracy at 0 degrees, but represents an indication of uncertainty rather than a maximum limit (particularly as temperatures diverge away from 0 degrees). See Doyle et al. (2018) and Miles et al. (2018) for more information.