five

micro-XRCT data sets and in situ measured ultrasonic wave propagation of pre-stressed monodisperse rubber and glass particle mixtures with 10%, 20%, and 30% volume rubber content: samples 2 and 3

收藏
Mendeley Data2024-03-27 更新2024-06-27 收录
下载链接:
https://darus.uni-stuttgart.de/citation?persistentId=doi:10.18419/darus-3437
下载链接
链接失效反馈
官方服务:
资源简介:
This dataset contains 12 micro X-ray Computed Tomography (micro-XRCT) data sets from scans of cylindrical particulate mixture samples (diameter 80 mm; unloaded height 80 mm) under different uniaxial compression loads. The samples consist of monodisperse stiff (glass) and soft (rubber) particle mixtures. Both particles have an identical diameter of 4 mm. The considered samples have a volume fraction of 10%, 20%, and 30% rubber particles. Two individual mixtures were investigated for each volume fraction. The scans were performed in a low X-ray absorbing transparent oedometer cell with an integrated pair of P-wave ultrasonic transducers to determine in situ the sample stiffness based on wave propagation velocity measurements. On both sides, the wave travels through a 10 mm long Poly (methyl methacrylate) (PMMA) pre-run and after-run section before and after the wave enters and leaves the sample. The respectively prepared sample inside the oedometer cell was uniaxially compressed in axial direction in subsequent force increments from F_stat. = 200 N to F_stat. = 1000 N (force-controlled) using a Universal Testing Machine (UTM) integrated into the XRCT system. At each force level, the system was relaxed for some time at the defined force to compensate the creep behavior of the soft particles. Subsequently, ultrasonic wave propagation measurements were performed at five different load levels, F_stat. = {200, 400, 600, 800, 1000} N. micro-XRCT scans were acquired in situ at F_stat. = {400, 800} N. For this, it was switched from force-controlled to displacement-controlled to avoid creeping and an eventual movement of the particles during the imaging. In this data set, the reconstructed 3d volumes (mixture_nu*_F400N_reconstructed.tar.gz and mixture_nu*_F800N_reconstructed.tar.gz), as well as the projection images (mixture_nu*_F400N_projections.tar.gz and mixture_nu*_F800N_projections.tar.gz) with * indicating the rubber volume fraction nu = {0.1, 0.2, 0.3} and the mixture counter {2, 3} for both preloads are given. For the datasets with counter 1 see the related datasets. The raw ultrasonic measurement data (transducer signals over time) is provided for all five preloads (mixture_nu*_ultrasonic_data.tar.gz), before and after the force-controlled relaxation, as an averaged signal of a stack of 32 signals. The file mixture_nu*_utm_data.csv contains the measured axial force and displacement from the UTM during the whole experiment. Based on the measured displacement of the UTM, the current mixture length was determined.
创建时间:
2023-06-28
二维码
社区交流群
二维码
科研交流群
商业服务